Views: 0 Author: Site Editor Publish Time: 2024-03-14 Origin: Site
Vrcoolertech CST manufactured an air preheater for a chile client.
Here are the process characteristics:
Hot side: 2,05 kg/s of moist air at T_in 110°C; P_in=400 Pa gauge,
Wet Bulb 70°C; T_out 65°C (Requires condensation to improve heat transfer)
Required thermal power app 150 kW
Cold side: ambient air; T_in 25°C; T_out not specified;
mass flow: 2,05 kg/s P_in 0 Pa gauge