Views: 0 Author: Site Editor Publish Time: 2026-07-15 Origin: Site
Seafood releases massive water vapor, brine, salt mist, protein sludge during freezing, so evaporators prioritize anti-corrosion, anti-frost blocking, easy washdown, hygiene.
Fin Spacing (Most critical parameter)
Seafood Type | Recommended Fin Pitch | Reason |
|---|---|---|
Raw shrimp, peeled shrimp | 10–12 mm | Balance heat transfer & frost resistance |
Squid, mussel, wet fish fillet | 12–16 mm | Heavy moisture, avoid rapid fin clogging |
Long-run production (>8h continuous) | Variable pitch 16–10 mm (inlet wide, outlet narrow) | Extend running time between defrosts |
Cooked seafood (low moisture) | 8–10 mm | Higher heat exchange efficiency |
Coil Tube & Fin Materials (Salt corrosion resistance first)
Top choice for seafood processing (shrimp line standard)
- Tube: SS316L stainless steel (resist brine, chloride salt pitting)
- Fins: SS316 stainless steel
Full stainless coil, electro-polished surface for easy chemical washing.
Cost-balanced alternative
- Tube: SS304 / SS316L
- Fins: 3003 aluminum with full epoxy anti-corrosion coating + hydrophilic coating
Suitable for low-salt seafood, cheaper than full SS coil.
❌ Avoid bare copper tube + bare aluminum fins for shrimp/salt seafood – fast corrosion & leak failure.
Defrost System
1. Hot gas defrost (first choice for seafood IQF)
Fast defrost, less water accumulation, lower energy vs electric defrost; ideal for continuous production lines.
2. Electric defrost: Small batch IQF lines, low production volume
3. Water defrost: Rarely used, excess moisture worsens frosting.
Add drain pan with slope, large drain outlet, anti-clog drain pipe to discharge salt defrost water quickly.
Fan & Airflow Design
- High airflow EC energy-saving fans (variable speed VFD)
- Uniform vertical airflow to fluidize seafood for individual quick freezing
- Fan motor with waterproof IP55/IP67 rating, washdown safe
- Air baffles to prevent short-circuit cold air, ensure all product contacts cold air
Application
1. Fluidized bed IQF (small shrimp, diced seafood): 10–12mm fixed fin, SS316 coil
2. Tunnel IQF (fish fillet, squid strips): Variable pitch 16–10mm coil, hot gas defrost
3. Spiral IQF (large shrimp, whole fish): Full SS coil, heavy-duty drain pan, EC variable fans
Can Crossflow Heat Exchangers Be Used in Both Heating And Cooling Applications?
Do You Offer Customization Options for The Ripening Air Cooler?
What Role Do Rotary Heat Exchangers Play in Flue Gas Denitrification in Thermal Power Plants?
Plate-Type Transformer Radiator for ONAN & ONAF Cooling Systems
Full 1:1 Direct Replacement Heat Pump Evaporator Coils for Global HVAC Retrofit Market
International Business:+86 0519 8878 2189
Domestic business:+86 0519 8878 2190