Using Dry Coolers and Plate Heat Exchangers to Create an Immersion Cooling System

Views: 1     Author: Site Editor     Publish Time: 2023-09-05      Origin: Site

Using Dry Coolers and Plate Heat Exchangers to Create an Immersion Cooling System for up to 15 Miners


Creating an immersion cooling system for up to 15 miners using dry coolers and plate heat exchangers is a viable way to effectively dissipate the heat generated by mining equipment. Immersion cooling involves immersing mining hardware in a dielectric fluid or mineral oil to dissipate heat more efficiently than traditional air-cooling methods. The method of setting up such a system is as follows:


Required components:

1. Mining equipment: You will need the mining hardware (ASIC miner or GPU) that you want to cool.

2. Dielectric fluid or mineral oil: Select a suitable dielectric fluid or mineral oil for submersion. These fluids should not be electrically conductive and should have good heat transfer properties.

3. Immersion tank: You need a tank or container large enough to hold the mining equipment and dielectric fluid. The tank should be watertight and able to support the weight of the submerged equipment.

4. Dry cooler: A dry cooler is an air-to-liquid heat exchanger used to dissipate heat after the dielectric fluid has cooled. It is usually placed outside a building or in a well-ventilated area. Dry coolers use ambient air to cool the liquid in a closed-loop system.

5. Plate heat exchanger: This heat exchanger is used to transfer heat from the mining hardware to the dielectric fluid. It is installed in a submerged tank and helps maintain a constant temperature within the fluid.


120KW Dry Cooler for immersion Cooling


Installation steps:

1. Prepare the tanks: Place the immersion tanks in a well-ventilated location. Make sure they are clean and free of contaminants.

2. Submerge the mining equipment: Carefully immerse the mining equipment in the dielectric fluid inside the immersion tank. Make sure the equipment is completely covered.

3. Attach plate heat exchanger: Install the plate heat exchanger in the immersion tank. This assembly will facilitate the transfer of heat from the mining equipment to the dielectric fluid.

4. Closed Loop System: Establish a closed loop system using piping and pumps to circulate the dielectric fluid between the submerged tank and the plate heat exchanger.

5. Connecting the dry cooler: Install the dry cooler outdoors or in a well-ventilated area. Connect it to a closed-loop system to dissipate the heat of the dielectric fluid.

6. Control system: Implement a control system with temperature sensors and pumps to maintain the required operating temperature of the dielectric fluid.

7. Monitoring and Maintenance: Monitor the system regularly to ensure efficient operation. Maintain the quality and cleanliness of the dielectric fluid to prevent conductivity problems.


bitcoin cooling dry cooler feedback


By setting up an immersion cooling system with dry coolers and plate heat exchangers, you can efficiently cool mining equipment while maintaining a controlled temperature within the dielectric fluid. This approach can help extend the life of mining hardware and improve its overall performance while reducing the need for conventional air conditioning systems.