Views: 0 Author: Site Editor Publish Time: 2026-11-17 Origin: Site
At CSTHEATEXCHANGER, we design and manufacture factory-assembled Through-Wall (Straddle & Plug-Type) Monoblock Refrigeration Units specifically engineered for fresh meat cold rooms, butcher shops, commercial abattoirs, supermarket carcass holding rooms, and meat distribution centers operating within the critical +1∘C to +6∘C fresh-chilled temperature envelope (supporting thermal cooling capacities across typical modular ranges from 1.5 kW to over 25 kW, compatible with eco-friendly R290, R448A, R449A, R452A, and R134a refrigerants). Featuring hermetic scroll/reciprocating compressors, microchannel or tube-fin condensers with variable-speed EC fans, sanitary food-grade evaporator sections with protective hydrophilic coatings, and integrated electronic hot-gas/electric defrost, CST wall monoblocks eliminate on-site copper brazing and vacuum charging, maintain stable 85%–90% relative humidity to minimize carcass weight shrinkage, prevent bacterial growth, and deliver true plug-and-play installation through standard insulated cold room wall panels.
Maintaining fresh beef, pork, lamb, and poultry in the +1∘C to +6∘C+1∘C to +6∘C range requires precise control over both dry-bulb air temperature and relative humidity (RH). Inadequate humidity control leads to surface dehydration ("shrinkage"), while temperature spikes promote microbial proliferation:
FRESH MEAT CHILLED STORAGE (+1°C TO +6°C) THERMAL PROFILE
======================= THROUGH-WALL MONOBLOCK INTEGRATION =======================
┌─────────────────────────────────────────────────────────────────────────────┐
│ [OUTDOOR / AMBIENT CONDENSING SECTION] │
│ • Weatherproof Casing with Hermetic Low-Noise Compressor │
│ • Microchannel / Finned-Tube Condenser with Stepless EC Inverter Fan │
│ • Pre-charged sealed refrigeration circuit (Zero on-site refrigerant work) │
└──────────────────────────────────────┬──────────────────────────────────────┘
│ [THROUGH-WALL INSULATED STRADDLE PLUG]
▼
======================= SEALED FRESH MEAT COLD ROOM (+1°C TO +6°C) ============
┌─────────────────────────────────────────────────────────────────────────────┐
│ [INDOOR SANITARY EVAPORATOR SECTION] │
│ • Gentle Laminar Airflow Distribution across hanging carcass rails / shelves│
│ • Maintains 85%–90% RH: Minimizes meat weight loss & prevents dark dry rims │
│ • Rapid temperature recovery after cold room door openings │
└─────────────────────────────────────────────────────────────────────────────┘ ================================================================================
CST THROUGH-WALL MONOBLOCK VS. TRADITIONAL SPLIT-SYSTEM REFRIGERATION
================================================================================
Evaluation Parameter CST Through-Wall Monoblock Unit Traditional Split Refrigeration System
--------------------------------------------------------------------------------
Installation Complexity Plug-and-Play (Mount in wall cutout)Complex field brazing, evacuation, charging
Refrigerant Leakage Risk Factory Hermetically Sealed CircuitField flare & braze joints prone to leaks
Relative Humidity (RH) Control Optimized Large Coil Area (85%–90% RH)Undersized coils cause dry air & meat shrink
Wall Footprint & Integration Compact straddle/saddle plug designBulky remote condensing piping runs
Defrost Cycling Impact Rapid Hot-Gas / Smart Electric DefrostProlonged defrost heats up fresh meat
Hygienic Cleanability Food-Safe Washable Evaporator CasingStandard commercial sheet metal rusts
Commissioning Time On-Site Same-Day Commissioning (< 2 Hours)2 to 3 Days on-site piping & electrical
Refrigerant Charge Volume Minimal Factory Charge (Eco-Friendly)Large liquid line charging requirement
================================================================================ Fresh meat loses moisture through evaporation if cold room air is too dry, leading to significant yield loss (up to 2%–4% carcass weight reduction) and darkening of the meat surface. CST through-wall monoblocks are engineered with large-surface-area evaporator coils operating at a close evaporating temperature difference (small ΔTΔT), ensuring high relative humidity (85%–90% RH) that keeps meat tender, retains natural bloom, and eliminates financial loss from drip shrinkage.
Traditional split refrigeration systems require on-site copper pipe welding, nitrogen purging, deep vacuuming, and field refrigerant charging—frequently introducing moisture and weld flux into the circuit. CST monoblock units are 100% assembled, pre-charged with eco-friendly refrigerant, and factory-tested under strict quality control, enabling rapid plug-and-play mounting into a standard wall panel cutout within hours.
Meat storage requires clean, corrosion-resistant construction that withstands humidity and organic fatty acids:
CST THROUGH-WALL MONOBLOCK ANATOMY
┌─────────────────────────────────────────────────────────────────────────┐
│ [1. EVAPORATOR (COLD ROOM INTERIOR)] │
│ • Heavy-duty aluminum fins with hydrophilic / epoxy coating. │
│ • Seamless deoxidized copper or AISI 304 stainless steel tubing. │
│ • Deep-sloped, heated stainless steel condensate drain pan. │
├─────────────────────────────────────────────────────────────────────────┤
│ [2. INSULATED THROUGH-WALL PLUG] │
│ • High-density polyurethane (PUR) injection (100 mm thermal barrier). │
│ • Prevents thermal bridging and eliminates exterior panel sweating. │
├─────────────────────────────────────────────────────────────────────────┤
│ [3. CONDENSER (OUTDOOR / PLANT INTERIOR)] │
│ • Microchannel or finned-tube condenser with low-noise EC fan. │
│ • Heavy galvanized steel casing with anti-corrosion powder coating. │
└─────────────────────────────────────────────────────────────────────────┘ The straddle plug section that penetrates the insulated cold room wall is pressure-injected with high-density polyurethane (PUR) insulation (100 mm thickness) with food-grade EPDM sealing gaskets, completely preventing thermal bridging, exterior condensation sweating, and energy loss.
Even at +1∘C to +6∘C+1∘C to +6∘C room temperatures, evaporator coils operating below freezing gradually accumulate frost. CST monoblock units feature automated hot-gas defrost circuits, which melt coil frost from the inside out in less than 5 to 8 minutes, preventing room temperature rise and protecting fresh meat quality during defrost cycles.
CSTHEATEXCHANGER MEAT MONOBLOCK PORTFOLIO
[1. CST-MBM-COMPACT (1.5 KW TO 4.5 KW)]
• Sized for small walk-in butcher cold rooms, restaurant meat lockers, and retail cold boxes (10 m³ to 35 m³).
• Single-phase power supply options; compact side-wall straddle mounting.
─────────────────────────────────────────────────────────────────────────────
[2. CST-MBM-STANDARD (5.0 KW TO 12.0 KW)]
• Engineered for supermarket meat preparation rooms, abattoir chill holding rooms (40 m³ to 120 m³).
• Dual-fan evaporator for deep laminar air throw across multi-tier carcass hanging rails.
─────────────────────────────────────────────────────────────────────────────
[3. CST-MBM-INDUSTRIAL (15.0 KW TO 25.0+ KW)]
• Heavy-duty twin-compressor units for industrial meat processing facilities and distribution hubs (150 m³ to 300+ m³). (Note: The following engineering parameters represent standard manufacturing design envelopes. Exact cooling capacities, dimensions, fan configurations, and mounting brackets are custom-tailored to specific cold room volume, daily meat loading throughput, and room insulation properties.)
================================================================================
CST WALL MONOBLOCK UNIT FOR FRESH MEAT (CST-MBM-MEAT SERIES)
================================================================================
Engineering Parameter Standard Manufacturing & Design Range
--------------------------------------------------------------------------------
Nominal Cooling Capacity Range 1.5 kW to 25.0+ kW (Custom Modular Sizing)
Operating Room Temperature Range+1°C to +6°C (+33.8°F to +42.8°F) Chilled Meat Envelope
Relative Humidity (RH) Envelope 85% to 90% RH (Optimized to prevent meat shrinkage)
Refrigerant Compatibility R290 (Propane), R448A, R449A, R452A, R134a, Low-GWP blends
Mounting Configuration Through-Wall Straddle / Drop-In Wall Plug-Type
Insulated Plug Thickness 80 mm to 120 mm Injected Polyurethane (PUR) Barrier
Compressor Technology Hermetic Scroll / Reciprocating with Thermal Overload
Condenser Heat Exchanger High-Efficiency Microchannel or Copper Tube-Aluminum Fin
Evaporator Heat Exchanger Hydrophilic Blue / Epoxy-Coated Aluminum Fins, Seamless Tubes
Defrosting Mechanism Automated Hot-Gas Defrost or Heavy-Duty Incoloy Electric Rods
Condensate Management Integrated Heated Auto-Evaporation Pan / External Drain
Fan Motor Technology High-Efficiency Inverter EC or Low-Noise IP54/IP55 AC Fans
Control Interface & Telemetry Digital Microprocessor Controller with Modbus RTU / RS485
Enclosure Casing Metallurgy Galvanized Steel with Baked Epoxy Powder Coat / Stainless Steel
Testing & Quality Assurance 100% Factory Run-Tested + Helium Mass Spectrometer Leak Tested
================================================================================ A through-wall monoblock is factory-sealed, pre-charged, and fully tested, eliminating on-site pipe brazing, vacuuming errors, and refrigerant leaks. It enables same-day installation through a simple wall cutout and delivers precise temperature and humidity control without consuming indoor floor space.
CST engineers the evaporator coil with generous heat transfer surface area and a moderate temperature difference (ΔTΔT) between evaporating refrigerant and room air. This gentle cooling process minimizes moisture condensation on the coil, keeping relative humidity high to protect carcass weight and freshness.
Yes. Our condensers feature wide fin spacing, tropicalized coil configurations, and variable-speed fan modulation, ensuring reliable condensing performance and stable +1∘C to +6∘C+1∘C to +6∘C room temperatures even during peak summer ambient heatwaves.
Preserve meat bloom, prevent carcass weight shrinkage, and ensure seamless cold-chain compliance with CSTHEATEXCHANGER:
Custom Through-Wall Monoblock Units for Fresh Meat Storage (+1°C to +6°C)
Hermetically Factory-Sealed & Pre-Charged for Fast Plug-and-Play Installation
High Relative Humidity Engineering (85%–90% RH) to Minimize Drip Shrinkage
Gentle Laminar Airflow Distribution for Uniform Meat Temperature Stability
Automated Rapid Hot-Gas Defrost to Prevent Room Temperature Fluctuations
Full Factory Run-Testing, 100%100% Helium Leak Tested & Fast Global Export
Contact our specialized food cold-chain engineering team with your cold room dimensions (L ×× W ×× H), daily fresh meat loading capacity (kg/day), wall insulation thickness, and target room temperature for detailed thermal load calculations and factory-direct proposals.
Website: https://www.cstheatexchanger.com/
Technical Inquiries: info@cstheatexchanger.com
International Business:+86 0519 8878 2189
Domestic business:+86 0519 8878 2190