At CSTHEATEXCHANGER, we engineer and manufacture Modular Coolant Distribution Units (CDUs) designed specifically for scalable, high-density AI server racks (40 kW to over 150 kW per enclosure), hyperscale GPU clusters (NVIDIA GB200 NVL72 / H100 / H200, AMD MI300X), and enterprise HPC liquid cooling deployments. Engineered around a modular slide-out architecture (4U to 8U rack-mount drawers and modular in-row frames), our modular CDUs feature hot-swappable N+1 pump trays with dripless quick disconnects (UQD), scalable AISI 316L / Titanium Brazed Plate Heat Exchanger (BPHE) modules, and master-slave multi-CDU load sharing. By providing complete hydraulic isolation between primary facility water (FWS) and secondary technology cooling loops (TCS) with an ultra-tight thermal approach temperature of 1.5K to 3.5K, CSTHEATEXCHANGER modular CDUs allow data centers to expand liquid cooling capacity incrementally rack-by-rack, perform zero-downtime hot maintenance, and operate with year-round 100% free cooling at sub-1.02 PUE.
Traditional monolithic liquid cooling systems require massive upfront capital expenditure and rigid piping headers. CSTHEATEXCHANGER modular CDUs enable a "pay-as-you-grow" modular thermal topology:
MODULAR CDU ARCHITECTURE & SCALABLE RACK-LEVEL INTEGRATION
=================== PRIMARY FACILITY WATER SYSTEM (FWS) ===================
[ Facility Water Header: +30°C to +42°C (Dry Coolers / Cooling Towers) ]
│ ▲
2-Way Modulating Valve FWR Return to Utility
│ │
▼ │
┌────────────────────────────────────────────────────────────────────────────┐
│ CSTHEATEXCHANGER® MODULAR CHASSIS (SLIDE-OUT DRAWER / IN-ROW ENCLOSURE) │
│ ┌────────────────────────────────────────────────────────────────────────┐ │
│ │ [MODULE 1: SCALABLE VACUUM-BRAZED BPHE CORE] │ │
│ │ • AISI 316L Stainless Steel / Titanium Plates (1.5K - 3.5K Approach) │ │
│ │ • Modular expandability: 40 kW -> 80 kW -> 120 kW -> 160 kW per rack │ │
│ └────────────────────────────────────────────────────────────────────────┘ │
│ ┌────────────────────────────────────────────────────────────────────────┐ │
│ │ [MODULE 2: HOT-SWAPPABLE N+1 PUMP CASSETTES WITH DRIPLESS UQDs] │ │
│ │ • Pump Tray 1 (Active) ◄─► Pump Tray 2 (Standby / Auto-Failover) │ │
│ │ • Live hot-swapping under full fluid pressure with zero system leakage │ │
│ └────────────────────────────────────────────────────────────────────────┘ │
│ ┌────────────────────────────────────────────────────────────────────────┐ │
│ │ [MODULE 3: INTEGRATED FLUID CONDITIONING & INTELLIGENT PLC SUITE] │ │
│ │ • Duplex 50 µm / 20 µm filter cartridges + Microbubble air deaerator │ │
│ │ • Redfish API / SNMP v3 / Modbus TCP automated load-sharing network │ │
│ └────────────────────────────────────────────────────────────────────────┘ │
└─────────────────────┬────────────────────────────────┬─────────────────────┘
│ ▲
Cold Coolant Supply: +35°C to +45°C Warm Return: +50°C to +65°C
│ │
▼ │
================ SECONDARY TECHNOLOGY COOLING SYSTEM (TCS) ================
[ High-Density Direct-to-Chip (DTC) Server Racks: 40 kW to 150 kW+ / Rack ] Our modular CDUs house independent pump cassettes connected via blind-mate dripless quick disconnect couplings (ISO 16028 / UQD) and internal isolation check valves. If a pump requires inspection or replacement, field technicians slide out the faulty pump cassette and insert a replacement in under 2 minutes without stopping coolant circulation, dropping loop pressure, or interrupting server compute workloads.
Multiple modular CDUs can be interconnected via Ethernet/CAN bus. An intelligent distributed PLC algorithm orchestrates dynamic flow balancing, allowing two 80 kW modular units to support a 150 kW rack or share cooling across neighboring racks during peak AI training workloads.
================================================================================
CSTHEATEXCHANGER MODULAR CDUs VS. CONVENTIONAL MONOLITHIC CDUs
================================================================================
Engineering Feature Conventional Central CDU CST Modular High-Density Rack CDU
--------------------------------------------------------------------------------
Deployment Scalability Rigid (All-or-Nothing Upfront) Modular "Pay-As-You-Grow" per Rack
Pump Maintenance & Replacement Requires Complete System Bypass Live Hot-Swappable Pump Tray (< 2 min)
Secondary Coolant Pipe Lengths Long Sub-Floor Distribution Short Direct In-Rack / In-Row Manifolds
Hydraulic Fluid Volume in Loop High Coolant Volume / High Risk Minimal Secondary Coolant Inventory
Thermal Approach Temperature 4.0K to 7.0K Ultra-Tight 1.5K to 3.5K Approach
Failure Blast Radius Central Point of Failure Isolated to Single Rack / Shared Pair
Control & Telemetry Centralized PLC Only Distributed Redfish API, SNMP v3, Modbus
Space Utilization Consumes Costly White Space Fits 4U-8U In-Rack or 300mm In-Row Slot
================================================================================ ZERO-DOWNTIME HOT-SWAP PUMP TRAY MECHANISM
SLIDE-OUT CASSETTE ENGAGEMENT
[ CDU CHASSIS ] ◄═════════════════════════════════════════════► [ PUMP TRAY ]
• Integrated Non-Spill UQD Coupling (Seals Automatically on Disconnect)
• Blind-Mate Multi-Pin Power & CAN-Bus Telemetry Interface
• Guide Rails for Precise Alignment & Single-Technician Extraction CSTHEATEXCHANGER offers modular liquid cooling CDUs across three flexible form factors:
CSTHEATEXCHANGER MODULAR CDU FORM FACTORS
[1. MODULAR IN-RACK CDUs (40 kW - 120 kW)]
• Form Factor: 4U / 5U / 6U / 8U EIA-310 19" or 21" OCP slide-out drawers.
• Ideal For: Direct deployment inside AI compute racks; completely self-contained.
─────────────────────────────────────────────────────────────────────────────
[2. MODULAR IN-ROW SIDECAR CDUs (150 kW - 450 kW)]
• Form Factor: Ultra-narrow 300 mm wide enclosure aligned with server rows.
• Ideal For: High-density rows sharing modular cooling across 3 to 6 AI cabinets.
─────────────────────────────────────────────────────────────────────────────
[3. MODULAR EXPANDABLE SKID CDUs (500 kW - 1.5 MW+)]
• Form Factor: Multi-bay modular frame allowing plug-in heat exchanger & pump blocks.
• Ideal For: Hyperscale pods requiring phased capital expenditure expansion. (Note: The following engineering parameters represent standard manufacturing design envelopes. Exchanger plate sizing, pump head pressures, and manifold quick disconnect layouts are customized to project requirements.)
================================================================================
CSTHEATEXCHANGER MODULAR COOLANT DISTRIBUTION UNIT (CST-MCDU SERIES)
================================================================================
Engineering Parameter Standard Manufacturing & Design Range
--------------------------------------------------------------------------------
Modular Cooling Capacity Range 40 kW to 150+ kW (In-Rack) | 150 kW to 600+ kW (In-Row)
Heat Exchanger Technology Modular Vacuum-Brazed Plate Heat Exchanger (BPHE)
Plate Metallurgy Options AISI 316L Stainless Steel (1.4404) or Titanium Gr. 1
Brazing Material Options Pure Copper (99.9%) or High-Purity Nickel Alloy (BNi-2)
Thermal Approach Temperature Ultra-Tight 1.5K to 3.5K @ Full Rated Heat Load
Secondary Coolant Flow Rate 40 to 200+ L/min (In-Rack) | Up to 800+ L/min (In-Row)
Secondary Differential Pressure 1.5 to 3.0 bar (21.7 to 43.5 psi) Variable Modulated
Pump Redundancy Architecture Modular N+1 / N+2 Hot-Swappable Canned-Motor / Mag-Drive Trays
Pump Hot-Swap Replacement Time < 2 Minutes Under Full Operating Pressure (Zero Spill)
Filtration System Standard Duplex 50 µm / 20 µm Filter Cartridges with ΔP Sensors
Primary Facility Water Temp +20°C to +45°C (Compatible with Free Cooling Dry Coolers)
Secondary Technology Supply +25°C to +50°C (Optimized for Direct-to-Chip Cold Plates)
Secondary Fluid Compatibility Deionized Water (DI-Water), PG25/EG25 (Inhibited Glycol)
Expansion & Air Separation Sealed Stainless Steel Vessel with Micro-Bubble Deaerator
Communication & DCIM Protocols Redfish API, SNMP v3, Modbus TCP/RTU, BACnet IP, Dual GbE LAN
Leak Detection & Containment Optical Sump Sensors, Perimeter Rope Sensor, Fast Auto-Shutoff
Hydraulic Couplings & ConnectorsBlind-Mate Non-Spill Universal Quick Disconnects (UQD)
Quality, Safety & EMC Codes UL 62368-1, CE / PED 2014/68/EU, RoHS, REACH, ISO 9001:2015
================================================================================ A modular CDU provides dedicated, localized thermal control directly adjacent to or inside the high-density rack. It eliminates massive sub-floor piping networks, significantly reduces secondary coolant volume, localizes failure risks to individual racks, and allows operators to scale capital investment proportionally as new GPU racks are deployed.
Each pump tray is mounted on precision guide rails and connects to internal manifolds using blind-mate non-spill Universal Quick Disconnects (UQDs) equipped with double shut-off poppet valves. When a pump cassette is withdrawn, internal mechanical springs instantly seal both fluid ports with zero liquid spillage, allowing live replacement under operating loop pressure.
Yes. CSTHEATEXCHANGER modular CDUs feature built-in master-slave communication. Multiple in-rack or in-row CDUs can link their control logic to dynamically balance secondary coolant flow and thermal loads across a cluster of interconnected server cabinets, providing N+1 or 2N system-level redundancy.
Maximize computing density, ensure zero-downtime scalability, and reduce data center PUE with CSTHEATEXCHANGER:
Modular In-Rack and In-Row CDUs
Hot-Swappable N+1 Pump Cassettes with Non-Spill Universal Quick Disconnects (UQDs)
High-Efficiency AISI 316L / Titanium Brazed Plate Heat Exchangers
Integrated Duplex 50 μm Filtration, Micro-Deaeration, and Expansion Buffers
Full Redfish API, SNMP v3, and Modbus TCP Data Center Infrastructure Integration
Custom OEM/ODM 3D CAD Engineering, Thermal Simulation & Global Direct Factory Supply
Contact our specialized liquid cooling engineering team today with your rack power density, allowable chassis dimensions (UU height / width), target fluid temperatures, and manifold specifications for customized engineering proposals and factory-direct quotations.
Website: https://www.cstheatexchanger.com/
Technical Inquiries: info@cstheatexchanger.com
Copper-Plated Steel Bundy Tube Condensers | CSTHEATEXCHANGER
Aluminum Roll Bond EV Battery Cooling Plates | CSTHEATEXCHANGER
3003 Aluminum Alloy Roll Bond Freezer Evaporators | CSTHEATEXCHANGER
Roll Bond Cooling Plates for Water Dispensers | CSTHEATEXCHANGER
1000kW Central Floor CDU for Liquid Cooling | CSTHEATEXCHANGER
Liquid-to-Liquid CDU vs. Liquid-to-Air CDU Guide | CSTHEATEXCHANGER
Modular CDU Liquid Cooling for High-Density Racks | CSTHEATEXCHANGER