At CSTHEATEXCHANGER, we design and manufacture high-efficiency Indirect Evaporative Cooling Air Handling Units (IEC AHUs / Evaporative Free-Cooling AHUs) specifically engineered for hyperscale cloud data centers, high-density AI compute clusters, colocation facilities, containerized modular data centers, and telecommunication switch rooms (cooling capacities engineered within typical modular ranges from 50 kW to over 450 kW per unit, airflow delivery from 8,000 m³/h to over 80,000 m³/h, achieving annual annualized PUE (Power Usage Effectiveness) ratings below 1.15 and ultra-low WUE (Water Usage Effectiveness), compatible with DX inverter trim compressors, chilled water auxiliary coils, and direct 380V/480V 3-phase power). Built with high-efficiency hydrophilic polymer / anti-corrosion aluminum cross-flow plate heat exchanger cores, multi-mode intelligent thermodynamic switching (Dry Mode, Wet Evaporative Mode, and Hybrid DX Mechanical Trim Mode), high-pressure atomizing water spray nozzles with automatic UV-C water disinfection and cyclic descaling, direct-drive high-static EC plug fans, and airtight dual-skin thermal-break casings (EN 1886 L1/T2/TB1), CST evaporative cooling AHUs maximize annual free-cooling hours up to 85%–95%, eliminate outdoor airborne particulate contamination from entering white space server rooms, reduce data center HVAC electrical consumption by up to 40%–60%, and ensure 24/7/365 thermal stability for high-density server racks.

Indirect Evaporative Cooling AHUs (IEC AHUs) for Hyperscale & AI Compute Data Centers.jpg

1. Thermodynamic & Operating Principle: 3-Stage Smart Mode Switching

Data center white space requires clean, uncontaminated air with zero outdoor moisture or pollution ingress. CST Indirect Evaporative Cooling AHUs separate the indoor process air stream (Secondary Air) from the outdoor scavenger cooling air stream (Primary Air) across an impermeable heat exchanger core:

        CST INDIRECT EVAPORATIVE COOLING AHU AIRFLOW & THERMAL CYCLE
        
   ======================= OUTDOOR SCAVENGER AIR + ATOMIZED WATER =======================
   (Primary Air: Draws outdoor ambient air + atomized water mist across wet channels)
   ┌──────────────────────────────────────────────────────────────────────────────────┐
   │ • Water evaporates in scavenger channels, absorbing latent heat of vaporization   │
   │ • Cools the heat exchanger channel walls down towards ambient wet-bulb temperature│
   │ • Exhausts warm, humid air outdoors (100% isolated; never touches server room)   │
   └────────────────────────────────────────┬─────────────────────────────────────────┘
                                            │ [LATENT & SENSIBLE HEAT TRANSFER ACROSS CORE]
                                            ▼
   ======================= SERVER ROOM RECIRCULATION AIR (WHITE SPACE) ================
   (Secondary Air: Hot server exhaust air at +36°C to +40°C from hot aisles)
   ┌──────────────────────────────────────────────────────────────────────────────────┐
   │ • Hot indoor server air passes through dry sealed interior channels              │
   │ • Chilled by wet channel walls down to +22°C to +25°C without adding moisture    │
   │ • Optional DX Inverter Trim Compressor / Chilled Water coil provides peak backup │
   └────────────────────────────────────────┬─────────────────────────────────────────┘
                                            │ [CLEAN, CONDITIONED COLD SUPPLY AIR]
                                            ▼
   ======================= DATA CENTER COLD AISLE SUPPLY (+22°C TO +25°C) =============
================================================================================
CST IEC AHU SMART 3-MODE OPERATING MATRIX
================================================================================
Operating Mode         Ambient Conditions           Active Subsystems           Energy & Water Profile
--------------------------------------------------------------------------------
1. Dry Free-Cooling    Winter / Cool Dry Seasons    Fans only; Dry Plate Core;  PUE < 1.08;
   Mode (No Water)     (Ambient Temp < +15°C)       Water spray & DX compressor OFFZero Water Consumption
--------------------------------------------------------------------------------
2. Wet Evaporative     Spring / Autumn / Moderate   Fans + High-Pressure Water  PUE < 1.15;
   Free-Cooling Mode   (Wet Bulb < +21°C)           Spray Pump; DX compressor OFFZero Compressor Energy
--------------------------------------------------------------------------------
3. Hybrid Evaporative  Hot & Humid Summer Peaks     Fans + Water Spray Mist +   PUE < 1.25;
   + DX Mechanical Trim(Ambient Wet Bulb > +22°C)   Variable Inverter DX Trim   Guarantees 100% Uptime
================================================================================

1. 100% Zero-Contamination Heat Transfer (No Outdoor Air Mixing)

Unlike direct evaporative cooling (DEC) systems that blow humid, dust-laden outdoor air directly into server rooms, CST’s indirect evaporative design ensures complete physical separation between outdoor air and indoor server recirculation air. Airborne dust, sulfur dioxide, salt spray, and outdoor humidity fluctuations cannot enter the white space, complying with strict ASHRAE TC 9.9 thermal and particulate standards.

2. High-Efficiency Polymer & Aluminum Evaporative Plate Cores

CST utilizes specially textured, hydrophilic-coated aluminum plates or anti-fouling engineered polymer heat exchanger matrixes. The micro-grooved surface promotes uniform water film spreading without dry spots, maximizing latent heat evaporation rates and achieving wet-bulb cooling efficiencies exceeding 75% to 85%.

2. Structural Metallurgy & Mechanical Architecture: Built for Hyperscale Reliability

Data center infrastructure requires continuous 24/7/365 run times, zero unplanned downtime, and low maintenance:

        CST IEC AHU STRUCTURAL ANATOMY & SUBSYSTEMS
        
   ┌─────────────────────────────────────────────────────────────────────────┐
   │ [1. EVAPORATIVE CORE & SPRAY WATER MANAGEMENT]                          │
   │ • Hydrophilic anti-corrosion plate core with 100% sealed seams.         │
   │ • Stainless steel 316L spray headers with non-clogging swirl nozzles.   │
   │ • Dual-stage water filtration, UV-C germicidal sterilizer & auto-drain. │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [2. HIGH-STATIC DIRECT-DRIVE EC PLUG BLOWERS]                           │
   │ • Parallel N+1 redundant backward-curved aluminum EC fan arrays.        │
   │ • Dynamic airflow modulation matching instantaneous server IT load.     │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [3. THERMAL-BREAK AIRTIGHT CASING (EN 1886 L1 / T2 / TB1)]              │
   │ • 50 mm double-skin polyurethane insulated panels with C5-M finish.     │
   │ • Integrated mechanical DX trim refrigeration circuit with R410A/R32.   │
   └─────────────────────────────────────────────────────────────────────────┘
       CST DATA CENTER IEC AHU PRODUCTION WORKFLOW
       
   FROM PRECISION DIE-FORMED HYDROPHILIC PLATES & STRUCTURAL PANELS
   ┌─────────────────────────────────────────────────────────────────────────┐
   │ [ STAGE 1: AUTOMATED CORE ASSEMBLY & SEALED LASER WELDING ]             │
   │ Precision robotic seam sealing guarantees zero air crossover leakage    │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 2: STAINLESS SPRAY SKID & UV-C STERILIZER INTEGRATION ]         │
   │ Heavy AISI 316L water distribution manifold with anti-scale purge logic │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 3: CASING AIR-TIGHTNESS & PRESSURE PROOF TESTING (EN 1886) ]    │
   │ Certified Class L1 airtightness at +/- 1,500 Pa static casing pressure  │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 4: FULL-LOAD 3-MODE THERMAL & ELECTRICAL COMMISSIONING ]        │
   │ Automated dry, wet, and DX trim operational mode changeover test        │
   └─────────────────────────────────────────────────────────────────────────┘
   DELIVERS MAXIMUM DATA CENTER PUE EFFICIENCY & CONTINUOUS UPTIME STABILITY

1. N+1 EC Plug Fan Array with Dynamic Power Scaling

To eliminate single-point mechanical fan failures, CST deploys direct-drive EC plug fan arrays configured in an N+1 or N+2 parallel redundancy matrix. If a single fan module faults, remaining blowers automatically ramp speed via Modbus/BACnet commands, maintaining uninterrupted airflow and server rack delta-P without thermal spikes.

2. Intelligent Water Quality & Automatic Anti-Scale Purge System

Water hardness and biological growth can foul evaporative cores. CST IEC AHUs incorporate automated electrical conductivity (TDS) sensors, automatic water dump/drain valves, multi-stage sediment filters, and inline UV-C germicidal lamps, preventing mineral scaling, algae, and Legionella formation while maximizing water recycling efficiency.

3. Product Variations: Data Center Evaporative Cooling AHU Series

        CSTHEATEXCHANGER IEC AHU PORTFOLIO
        
   [1. CST-IEC-ROOFTOP (ROOFTOP PACKAGED EVAPORATIVE AHU)]
   • Capacities: 100 kW to 450+ kW.
   • Sized for top-ducted modular data centers, hyperscale multi-story facilities, and flat-roof server halls.
   ─────────────────────────────────────────────────────────────────────────────
   [2. CST-IEC-PERIMETER (SIDE-WALL / PERIMETER YARD-MOUNTED AHU)]
   • Capacities: 50 kW to 300 kW.
   • Installed on building perimeter walls or outside containerized computing corridors.
   ─────────────────────────────────────────────────────────────────────────────
   [3. CST-IEC-MODULAR (CONTAINERIZED EDGE AI DATA CENTER MODULES)]
   • Fully packaged, self-contained evaporative cooling modules for mobile AI supercomputing pods.

4. Technical Specifications — Data Center Indirect Evaporative Cooling AHU

(Note: The following engineering parameters represent standard manufacturing design envelopes. Exact dimensions, cooling capacity, air volume, static pressure, and DX trim configurations are custom-tailored to specific server rack heat densities, indoor temperature targets, and local ambient climate weather data.)

================================================================================
CST DATA CENTER INDIRECT EVAPORATIVE COOLING AHU (CST-IEC-SERIES)
================================================================================
Engineering Parameter           Typical Manufacturing & Design Range (Indicative)
--------------------------------------------------------------------------------
Total Cooling Capacity Range    50 kW to 450+ kW per Modular Unit (Custom Scalable)
Supply Airflow Volume Capacity  8,000 m³/h to 80,000+ m³/h (Variable Airflow)
Annualized Data Center PUE      1.08 to 1.15 (Dependent on Regional Climate Zone)
Heat Exchanger Core Technology  High-Efficiency Hydrophilic Polymer or Aluminum Plate
Core Wet-Bulb Efficiency Rate   75% to 85%+ Indirect Evaporative Effectiveness
Operating Mode Capabilities     3-Stage Auto Switching: Dry Free-Cool / Wet IEC / DX Trim
Process Air Supply Temperature  +20°C to +27°C (Complying with ASHRAE TC 9.9 A1/A2)
Process Air Supply RH Control   Zero Moisture Addition (Closed Recirculation Loop)
Auxiliary Mechanical Cooling    Integrated Variable-Speed Inverter DX Scroll / CHW Coil
Refrigerant Compatibility       R410A, R32, Low-GWP Refrigerant Blends
Water Spray & Atomization Suite High-Pressure 316L Stainless Header + Non-Clog Nozzles
Water Quality & Sanitation      Automatic TDS Conductivity Purge + Inline UV-C Sterilizer
Fan & Blower Architecture       Direct-Drive EC Plug Fan Wall (N+1 Redundancy Matrix)
Casing Construction & Thermal   50 mm Double-Skin Polyurethane (T2 / TB1 / Class L1 Airtight)
External Casing Finish          ISO 12944 C4 / C5-M Heavy Industrial & Marine Epoxy Coat
Control & Telemetry Interface   Siemens / Schneider PLC Touchscreen with SNMPv3, BACnet, Modbus
Testing & Quality Assurance     100% Mass Spectrometer Helium Leak Tested + Full Mode Run Test
================================================================================

5. Frequently Asked Questions (FAQ)

How does an Indirect Evaporative Cooling AHU achieve a PUE below 1.15?

Unlike conventional chilled water CRAC units that rely on energy-intensive chillers and compressors 24/7, an IEC AHU utilizes the natural evaporation of water in outdoor scavenger air channels to cool indoor server air. Mechanical DX compressors are only activated during extreme summer heatwaves, allowing the unit to operate in ultra-low-energy free-cooling modes for up to 80%–90% of the year.

Does an indirect evaporative cooling system add humidity to the server room?

No. The water spray and evaporation process occurs entirely within the outdoor primary air stream. The indoor server room air circulates through completely sealed, impermeable secondary channels, transferring heat without any moisture transfer, chemical crossover, or outdoor air introduction into the white space.

What happens during freezing winter weather?

During sub-zero winter temperatures, the unit automatically switches to Dry Free-Cooling Mode. The water circuit is completely drained into an internal frost-protected sump, and the dry plate heat exchanger transfers heat directly to cold outdoor air with zero water consumption and zero risk of freezing.

Engineering Checklist for Data Center IEC AHU Sizing (Customer Confirmation Required)

To provide an exact custom thermodynamic simulation, annualized PUE calculation, and CAD equipment drawing for your data center project, our engineering team requires confirmation of the following site parameters:

================================================================================
PROJECT PARAMETERS FOR CUSTOM DATA CENTER IEC AHU SIZING
================================================================================
1. IT Thermal Heat Load:       Total server room heat dissipation (kW or MW)
2. Supply Air & Temperature:   Required cold aisle supply temp (°C) & return hot aisle temp (°C)
3. Total Airflow Volume:       Target process air volume (m³/h or CFM)
4. Local Ambient Climate Data: Peak Summer Dry/Wet Bulb (°C) & Winter Min Temp (°C)
5. Physical Layout & Mount:    Rooftop Packaged, Side-Wall Yard, or Containerized Pod
6. Auxiliary Cooling Type:     Integrated Variable Inverter DX Compressor or Chilled Water (CHW)
7. Power Supply Standards:     380V/400V/480V 3-Phase (50/60 Hz)
8. Water Supply Conditions:    City tap water, RO purified water, or industrial recycled water
================================================================================

Source Custom Data Center IEC AHUs from CSTHEATEXCHANGER

Slash data center energy bills, achieve target PUE < 1.15, and secure zero-contamination server room cooling with CSTHEATEXCHANGER:

  • Custom Data Center Indirect Evaporative Cooling AHUs (50 kW to 450 kW+)

  • Hydrophilic Polymer & Aluminum Indirect Plate Cores with >75% Wet-Bulb Efficiency

  • Intelligent 3-Mode Thermodynamic Controller (Dry Free-Cooling / Wet IEC / DX Trim)

  • N+1 Parallel Direct-Drive EC Plug Fan Wall Arrays for Zero-Downtime Reliability

  • Automatic Water Quality Conductivity Purge & Inline UV-C Disinfection Protection

  • Full Factory Pre-Commissioning & Global Direct Export

Contact our specialized hyperscale data center thermal management engineering team with your IT rack heat load, server room layout, and local climate data for detailed PUE simulations and factory-direct proposals.

PHONE

International Business:+86 0519 8878 2189

Domestic business:+86 0519 8878 2190

QUICK LINKS

PRODUCTS

ABOUT US

When it comes to building heat exchanger for any application VRCOOLERTECH has the capability to meet your requirements.
Copyright © 2021 Changzhou Vrcoolertech Refrigeration Co.,Ltd All rights reserved.  Sitemap  Manage Entrance