Views: 0 Author: Site Editor Publish Time: 2026-11-24 Origin: Site
At CSTHEATEXCHANGER, we design and manufacture custom-engineered evaporator coils specifically for commercial ceiling cassette air conditioners, VRF/VRV indoor units, multi-split systems, and hydronic chilled water cassette units. Ceiling cassette air conditioners (4-way blow, 2-way blow, 1-way slim, and 360° circular round-flow units) operate inside tight architectural ceiling voids (chassis heights from 210 mm to 290 mm), demanding ultra-compact wrap-around coil geometries, quiet aerodynamic airflow, and zero condensate spitting. CSTHEATEXCHANGER cassette evaporators utilize inner-grooved micro-bore copper tubes (5 mm, 7 mm, 9.52 mm), hydrophilic louvered aluminum fins, balanced multi-circuit Venturi distribution, and certified high-pressure containment (up to 4.5 MPa / 45 bar for R32 and R410A).
Ceiling cassette indoor units are among the most popular commercial HVAC terminal units for modern offices, hotels, retail stores, and restaurants due to their flush-mounted ceiling integration and multi-directional air distribution.
However, designing an evaporator coil for a ceiling cassette presents strict engineering constraints:
Shallow Ceiling Void & Low-Profile Height Limits: Modern architectural drop-ceilings provide minimal vertical clearance. The cassette chassis must maintain an ultra-compact height (often under 230 mm for compact 600×600 mm grids and under 290 mm for standard 900×900 mm units). The evaporator coil must deliver high cooling duty within a shallow multi-bend perimeter wrap.
Centrifugal Turbo Fan & Airflow Uniformity: Cassette units house a central backward-curved turbo fan that draws return air vertically through the central grille and blows it radially outward through the surrounding evaporator coil. If the multi-sided coil has uneven fin density or unbalanced circuit resistance, air velocity becomes turbulent, generating excessive aerodynamic whistling noise and creating localized warm air discharge corners.
Condensate Water Droplet Carryover ("Condensate Spitting"): High air velocity across the coil face can lift accumulated condensate droplets off the fins and spit water through the supply air louvers into occupied rooms. Coils require superior hydrophilic surface tension control and smooth gravity drainage paths.
Complex Multi-Corner Wrap-Around Bending: 4-way cassette coils undergo multi-stage precision CNC hairpin bending (four 90-degree corner bends or continuous circular arcs). Bending multi-row finned tube assemblies without tube flattening, fin crumpling, or internal hair-line stress fractures requires advanced tooling.
At CSTHEATEXCHANGER, we engineer every cassette evaporator coil with specialized micro-geometry, automated multi-axis bending, and precision refrigerant circuiting:
CSTHEATEXCHANGER® 4-WAY CASSETTE EVAPORATOR ARCHITECTURE
┌────────────────────────────────────────────────────────────────────────┐
│ High-Pressure Refrigerant Liquid Line (R32 / R410A / R454B / DX Feed) │
│ • Precision Venturi Distributor Header with Equal-Length Capillaries │
├────────────────────────────────────────────────────────────────────────┤
│ 4-Sided Continuous Wrap-Around Formed Coil Matrix (90° Corner Bends) │
│ │
│ ◄◄◄ Radial Airflow from Central Turbo Fan (Quiet Aerodynamic Stream) │
│ │
│ ══════════════════════════════════════════════════════════════════════ │
│ Inner-Grooved Seamless Copper Micro-Tubes (5 mm / 7 mm / 9.52 mm OD) │
│ Blue Hydrophilic Louvered Aluminum Fins (Anti-Spitting Surface Film) │
│ ══════════════════════════════════════════════════════════════════════ │
│ │
│ ►►► 4-Way Uniform Conditioned Supply Air Discharge into Room │
├────────────────────────────────────────────────────────────────────────┤
│ Integrated Return Suction Manifold with Factory Temperature Sensor Well│
├────────────────────────────────────────────────────────────────────────┤
│ Direct Interface with Cassette Condensate Lift Pump Drain Pan │
└────────────────────────────────────────────────────────────────────────┘ CSTHEATEXCHANGER incorporates high-efficiency inner-grooved seamless copper tubes. Internal helical micro-fins multiply the internal surface area and induce swirling annular thin-film boiling, boosting the internal refrigerant heat transfer coefficient by up to 220% compared to smooth-bore tubes. The smaller 5 mm and 7 mm tube diameters allow for compact coil packaging, reduce total equipment weight by up to 30%, and cut expensive refrigerant charge volume by over 40%.
Our fins are stamped with high-precision multi-slit louver patterns that disrupt boundary layers, maximizing airside heat transfer at low fan speeds. The aluminum surface features a durable blue hydrophilic coating that reduces water contact angle to under 15°, causing condensate to form a smooth, continuous water film that drains quickly into the lower drain pan without forming bridge droplets that cause airside water spitting.
We utilize automated multi-head CNC coil bending machines that form flawless 4-way rectangular wrap-around coils and circular 360-degree round-flow coils. Bending mandrels support internal tubes throughout the bend radius, maintaining cross-sectional tube ovality within 95%+ and preventing fin crumpling or localized air bypass gaps.
To eliminate uneven corner cooling, CSTHEATEXCHANGER engineers precision brass Venturi distributors paired with calibrated equal-length capillary distribution tubes. Liquid-vapor refrigerant mixture is injected equally across all parallel circuits, ensuring uniform evaporating temperatures and equal superheat across all 4 discharge louvers.
4-Way Blow Ceiling Cassettes: Standard 600×600 mm compact and 840×840 mm standard ceiling grid indoor units for offices, classrooms, and retail shops.
Round-Flow / 360° Circular Cassettes: Circular continuous curved evaporator coils delivering 360-degree seamless air distribution without corner dead zones.
1-Way & 2-Way Slim Cassettes: Linear evaporator coils designed for narrow hotel guestroom entry foyers and residential corridors.
Hydronic Chilled Water Cassette Fan Coils (FCU): Multi-row 2-pipe and 4-pipe chilled water and hot water coils for central chiller building loops.
High-Capacity Commercial VRF / Multi-Split Indoor Units: Heavy-duty DX evaporator coils for large open-plan spaces requiring 10 kW to 16 kW cooling duty per cassette chassis.
Cooling Capacity Range: 2.2 kW to 16.0 kW per cassette unit (0.75 Ton to 4.5 Tons of Refrigeration).
Airflow Volume: 450 m³/h to 2,400 m³/h.
Tube Diameters Available: 5.0 mm, 7.0 mm, 7.94 mm (5/16"), and 9.52 mm (3/8") OD inner-grooved seamless copper.
Fin Pitch / Spacing: 1.2 mm to 1.8 mm (14 to 21 Fins Per Inch) for optimal sensible and latent heat balance.
Refrigerant Compatibility: Direct Expansion (DX) R32, R410A, R454B, R134a, R407C, and Chilled Water / Glycol.
Operating Design Pressure: 4.2 MPa to 4.5 MPa (42 to 45 bar / 610 to 650 PSI); factory tested to 6.5 MPa.
Leak Detection Standards: 100% helium mass spectrometer vacuum chamber leak testing (<1×10⁻⁶ mbar·l/s).
Uncoated aluminum fins cause condensate to form rounded water beads that bridge fin gaps. High fan air velocity can pick up these beads and blow water droplets out of the cassette louvers. CSTHEATEXCHANGER hydrophilic blue fins force water to spread out into a continuous micro-thin film, allowing it to sheet down cleanly into the drain pan without droplet entrainment.
Smaller 5 mm and 7 mm tubes allow for tighter tube row spacing and higher fin surface area within shallow cassette heights. The inner micro-grooves provide superior boiling heat transfer, allowing the unit to achieve high SEER/SCOP energy ratings with significantly lower refrigerant charge.
Yes. We manufacture custom OEM and drop-in replacement cassette evaporator coils matching existing chassis mounting brackets, electronic expansion valve (EEV) mounts, temperature sensor thermowells, and connection tube centerlines.
Contact CSTHEATEXCHANGER today with your cassette air conditioning specifications:
Cassette Type: 4-Way Blow, Round-Flow 360°, 1-Way Slim, or 2-Way Dual Blow
Nominal Cooling Capacity (kW / BTU/h / Tons)
Refrigerant Type (R32, R410A, R454B) or Chilled Water Design
Coil Geometry & Chassis Height (mm / inches)
Tube Diameter Preference (5 mm, 7 mm, or 9.52 mm) & Fin Density (FPI)
Our thermal engineering team will provide detailed thermodynamic calculations, refrigerant pressure drop simulations, 3D CAD dimensional drawings, and factory-direct OEM pricing.
Website: https://www.cstheatexchanger.com/
Technical Inquiries: info@cstheatexchanger.com
International Business:+86 0519 8878 2189
Domestic business:+86 0519 8878 2190