At CSTHEATEXCHANGER, we design and manufacture extreme-pressure Transcritical CO2 (R744) Dry Coolers and Air-Cooled Gas Coolers specifically engineered for Liquefied Natural Gas (LNG) vehicle fueling stations, L-CNG mother/daughter stations, cryogenic Boil-Off Gas (BOG) re-liquefaction skids, and natural gas liquefaction precooling loops (handling thermal heat rejection loads from 50 kW to over 1,500 kW, operating at design pressures up to 13.0–15.0 MPa / 130–150 bar (1,885–2,175 psi), with gas operating temperatures up to +150∘C+150∘C and sub-zero winter ambient conditions down to −40∘C). Constructed with seamless heavy-wall K65 high-strength copper alloy or AISI 316L/316Ti stainless steel high-pressure tubes, epoxy/hydrophilic blue aluminum fins, explosion-proof ATEX/IECEx certified EC variable-speed fan arrays, and heavy-duty structural steel frames, CST CO2 dry coolers safely dissipate heat from supercritical CO2 re-liquefaction compressors, eliminate water consumption, prevent flammable gas ignition hazards, and guarantee 24/7/365 continuous LNG station dispensing uptime.

High-Pressure Transcritical CO2 Dry Coolers & Gas Coolers for LNG Gas Filling Stations.jpg

1. Thermodynamic & Cryogenic Engineering: The Role of CO2 Gas Coolers in LNG Stations

In modern LNG dispensing and L-CNG vehicle stations, cryogenic LNG stored at −162∘C−162∘C continuously generates Boil-Off Gas (BOG) due to ambient heat ingress. Eco-friendly Transcritical CO2 (R744) refrigeration cycles are increasingly deployed to re-condense BOG back into liquid LNG. The CST CO2 dry cooler acts as the high-pressure supercritical heat rejection interface:

        LNG STATION CRYOGENIC BOG RE-LIQUEFACTION & CO2 DRY COOLER LOOP
        
   ================== TRANSCRITICAL CO2 REFRIGERATION SKID ==================
   ┌────────────────────────────────────────────────────────────────────────┐
   │ [BOG CONDENSER / SUB-COOLER] ◄── Cryogenic BOG Vapor (-140°C to -100°C)│
   │ (R744 absorbs heat from boil-off natural gas, condensing it to LNG)    │
   └───────────────────────────────────┬────────────────────────────────────┘
                                       │
                                       ▼ [HIGH-PRESSURE CO2 COMPRESSOR DISCHARGE]
   ┌────────────────────────────────────────────────────────────────────────┐
   │ Supercritical CO2 Fluid (+90°C to +130°C @ 90–120 Bar High Pressure)   │
   └───────────────────────────────────┬────────────────────────────────────┘
                                       │
                                       ▼
   ================== OUTDOOR HAZARDOUS ZONE CO2 DRY COOLER ================
   ┌────────────────────────────────────────────────────────────────────────┐
   │ [CST HIGH-PRESSURE (150 BAR) AIR-COOLED CO2 GAS COOLER]                │
   │ • Seamless K65 Copper-Iron / AISI 316L Stainless Tubes (Burst > 450 bar)│
   │ • Heavy-wall staggered multi-pass headers with orbital TIG welds       │
   │ • ATEX/IECEx Explosion-Proof EC Variable-Speed Fan Arrays              │
   │ • Supercritical Gas De-superheating & Cooling (Exits at +32°C to +38°C)│
   └───────────────────────────────────┬────────────────────────────────────┘
                                       │
                                       ▼ [SUB-COOLED SUPERCRITICAL CO2 FLUID]
   ┌────────────────────────────────────────────────────────────────────────┐
   │ Returns to R744 Expansion Valve & BOG Heat Exchanger Loop              │
   └────────────────────────────────────────────────────────────────────────┘
================================================================================
CST TRANSCRITICAL CO2 DRY COOLER VS. TRADITIONAL WATER COOLING TOWERS IN LNG
================================================================================
Evaluation Metric              CST High-Pressure CO2 Dry Cooler Traditional Open/Closed Water Tower
--------------------------------------------------------------------------------
Working Pressure Capability    130 to 150 Bar (13.0–15.0 MPa)   Cannot handle transcritical R744 directly
Water Consumption Rate         0 Liters/Hour (100% Waterless)   Massive daily water evaporation & makeup
Explosion-Proof Compliance     ATEX / IECEx Zone 1 / Zone 2 RatedStandard non-classified water tower motors
Sub-Zero Freeze Hazard (-40°C) Zero Freeze Risk (CO2 gas/fluid) Severe ice damage in water basins/pipes
Refrigerant Environmental GWP  GWP = 1, ODP = 0 (Natural R744)  Legacy synthetic HFCs (High GWP taxes)
Maintenance Overhead           Minimal (Annual coil washdown)   Heavy chemical treatment & scale removal
Footprint & Site Integration   Self-Contained Modular V-Bank SkidRequires pumps, chemical dosing & sump
================================================================================

1. Ultra-High Operating Pressure Rating (130–150 Bar130–150 Bar)

Supercritical carbon dioxide operates above its thermodynamic critical point (+31.1∘C+31.1∘C and 7.38 MPa7.38 MPa). CST designs its CO2 gas coolers for continuous operating pressures up to 130–150 bar130–150 bar with hydrostatic proof testing exceeding 200 bar200 bar (and burst pressures >450 bar>450 bar), safely containing supercritical R744 discharge under all ambient conditions.

2. 100%100% Waterless Operation & Anti-Freezing in Extreme Climates

LNG fueling stations are often situated along remote highways or industrial transport corridors without municipal water access. CST dry coolers operate completely dry with zero water consumption, eliminating freezing risks in −40∘C−40∘C winter conditions and preventing water scaling on tubes.

2. Metallurgy & Manufacturing Engineering: High-Pressure Containment & Safety

Handling supercritical CO2 alongside flammable natural gas vapors requires specialized metallurgy and explosion-proof electrical construction:

        CST CO2 DRY COOLER HIGH-PRESSURE METALLURGY
        
   ┌─────────────────────────────────────────────────────────────────────────┐
   │ [1. HIGH-PRESSURE CORE TUBE ALLOY]                                      │
   │ • K65 High-Strength Copper-Iron Alloy (CuFe2P / CW107C) rated to 130 bar│
   │ • Heavy-Wall Seamless AISI 316L / 316Ti Stainless Steel (up to 150 bar).│
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [2. HIGH-FLUX HEAT REJECTION FINS]                                      │
   │ • Hydrophilic Blue Aluminum / Epoxy-Coated Corrugated Fins (Anti-salt). │
   │ • High-density sine-wave fin geometry maximizes gas-side cooling.       │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [3. EXPLOSION-PROOF ATEX / IECEx FAN MOTORS & CASING]                   │
   │ • Spark-proof composite fan blades with ATEX Zone 1/2 Ex d/Ex e motors. │
   │ • 2.5 mm Heavy Galvanized Steel with C5-M Marine/Industrial Coating.   │
   └─────────────────────────────────────────────────────────────────────────┘
       CST HIGH-PRESSURE CO2 GAS COOLER PRODUCTION WORKFLOW
       
   FROM CERTIFIED SEAMLESS K65 / 316L HIGH-PRESSURE TUBES
   ┌─────────────────────────────────────────────────────────────────────────┐
   │ [ STAGE 1: AUTOMATED CNC FIN PUNCHING & HIGH-PRESSURE EXPANSION ]       │
   │ Precision mechanical bullet expansion creates 100% metal-to-metal bond  │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 2: CLEANROOM ORBITAL TIG / HIGH-SILVER AUTOMATIC BRAZING ]      │
   │ Specialized Ag56 silver braze or TIG welding with inert argon purging   │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 3: 100% ULTRA-HIGH HYDROSTATIC PROOF TESTING (225 BAR) ]        │
   │ Tested at 1.5x design pressure to ensure zero metallurgical defects     │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 4: HELIUM VACUUM MASS SPECTROMETER LEAK VERIFICATION ]          │
   │ Certified leak-tight integrity (Leak rate < 1x10⁻⁶ mbar·L/s)            │
   └─────────────────────────────────────────────────────────────────────────┘
   GUARANTEES 100% EXPLOSION SAFETY & PRESSURE INTEGRITY AT LNG SITES

1. K65 Copper-Iron Alloy & AISI 316L Heavy Stainless Construction

K65 alloy combines the high thermal conductivity of copper with the mechanical tensile strength of alloyed iron, allowing thinner tube walls for superior heat flux while safely withstanding 130 bar130 bar working pressures. For highly corrosive industrial environments, AISI 316L/316Ti stainless steel tubes provide ultimate pressure containment up to 150 bar150 bar.

2. Certified ATEX / IECEx Explosion-Proof Fan Drive Architecture

Because LNG stations are classified hazardous zones (Zone 1 / Zone 2, Class I Div 2), standard commercial fan motors represent a potential ignition hazard. CST equips its gas coolers with ATEX/IECEx certified explosion-proof EC or AC motor fan assemblies with anti-static spark-proof fan blades.

3. Standard Product Configurations: LNG Station CO2 Dry Cooler Series

        CSTHEATEXCHANGER LNG STATION CO2 COOLER PORTFOLIO
        
   [1. CST-CO2-DC-100 (SMALL SKID & PILOT BOG CONDENSER)]
   • Capacity: 50 kW to 150 kW; Single V-Bank or Flat-Bed; Operating Pressure: 130 bar.
   • Ideal for compact containerized LNG dispensing skids and small fleet refueling points.
   ─────────────────────────────────────────────────────────────────────────────
   [2. CST-CO2-DC-500 (STANDARD COMMERCIAL LNG STATION BOG SYSTEM)]
   • Capacity: 200 kW to 600 kW; Modular V-Bank with 4 to 8 ATEX fan arrays.
   • Sized for high-throughput commercial truck LNG stations and L-CNG mother stations.
   ─────────────────────────────────────────────────────────────────────────────
   [3. CST-CO2-DC-1200+ (CENTRALIZED LNG TERMINAL & LIQUEFACTION PLANT)]
   • Capacity: 700 kW to 1,500+ kW; Dual V-Bank mega-modules with redundant fan clusters.
   • Engineered for multi-megawatt regional LNG satellite stations and peak-shaving facilities.

4. Technical Specifications — High-Pressure CO2 Dry Coolers for LNG Stations

(Note: The following engineering parameters represent standard manufacturing design envelopes. Operating pressure, gas flow rate, coil geometry, explosion-proof ratings, and casing dimensions are 100% custom-tailored to the LNG station refrigeration skid blueprints.)

================================================================================
CST HIGH-PRESSURE CO2 DRY COOLER (CST-LNG-CO2-SERIES)
================================================================================
Engineering Parameter           Standard Manufacturing & Design Range
--------------------------------------------------------------------------------
Thermal Heat Rejection Capacity 50 kW to 1,500+ kW (170,000 to 5,100,000+ BTU/h)
Operating Fluid Medium          Transcritical Carbon Dioxide (R744 / Supercritical CO2)
Design Operating Pressure Range 13.0 MPa to 15.0 MPa (130 to 150 bar / 1,885–2,175 psi)
Hydrostatic Proof Test Pressure 20.0 MPa to 22.5 MPa (200 to 225 bar / 2,900–3,260 psi)
Burst Pressure Rating           Exceeds 45.0 MPa (450 bar / 6,525 psi) Safety Factor > 3.0
CO2 Gas Inlet Temperature Range +80°C to +150°C (+176°F to +302°F) Supercritical Discharge
CO2 Gas Outlet Temperature      Approaching Ambient +2 K to +5 K (+32°C to +38°C typical)
Core Tube Metallurgy Options    K65 High-Strength Copper-Iron (CuFe2P) or AISI 316L/316Ti
Tube Outside Diameter (OD)      5/16" (7.94 mm), 3/8" (9.52 mm), 1/2" (12.7 mm) Heavy-Wall
Fin Metallurgy & Surface Finish Corrugated Hydrophilic Blue Al, Epoxy-Coated, or AlMg3
Fin Density Envelope            10 to 16 FPI (Optimized for dust shedding & low air dP)
Coil Form Factor & Geometry     Modular V-Bank, Horizontal Flat-Bed, or Vertical Slab
Fan Motor Explosion-Proof Spec  ATEX / IECEx Ex d IIB+H2 T4 / Ex e Certified Fan Drives
Fan Drive Technology            High-Efficiency Inverter EC or Explosion-Proof AC Motors
Acoustic Noise Pressure Level   Standard: 65–72 dBA @ 10m; Whisper-Quiet Package: < 58 dBA @ 10m
Structural Casing Metallurgy    2.5 mm Hot-Dip Galvanized Steel with C4/C5-I Industrial Coating
Refrigerant Port Connections    High-Pressure K65 Solder Sockets or Stainless Steel Welded Stubs
Quality Standards & Compliance  CE / PED 2014/68/EU Module H/H1, ASME Section VIII Div. 1, ATEX
Testing & Quality Assurance     100% Helium Mass Spectrometer Testing + 225 Bar Hydrostatic Proof
================================================================================

5. Frequently Asked Questions (FAQ)

Why is a transcritical CO2 (R744) dry cooler used in LNG filling stations instead of traditional refrigerants?

Carbon dioxide (R744) is a natural, non-toxic, non-flammable refrigerant with zero Ozone Depletion Potential (ODP=0ODP=0) and Global Warming Potential (GWP=1GWP=1). In LNG BOG re-liquefaction, CO2 provides exceptional low-temperature thermodynamic performance, allowing compact compressor skids that operate safely in hazardous gas station environments without synthetic chemical restrictions.

How does the gas cooler maintain safety under extreme 130–150 bar operating pressures?

CST utilizes seamless high-strength K65 alloy or heavy-wall AISI 316L stainless steel tubes, automated orbital TIG / high-silver brazing, and thick-walled forged manifolds. Every completed unit is hydrostatically proof-tested at 200–225 bar200–225 bar and vacuum helium tested, delivering a bursting safety factor exceeding 3.0×3.0× design pressure.

Can CST provide full explosion-proof ATEX/IECEx certification for hazardous zone placement?

Yes. We supply fully compliant ATEX (Directive 2014/34/EU) and IECEx certified units equipped with explosion-proof motors, anti-spark copper/aluminum fan diffusers, static-dissipative composite blades, and cast-iron Ex d junction boxes, certified for safe operation in Zone 1 and Zone 2 hazardous gas atmospheres.

Source Custom High-Pressure CO2 Dry Coolers from CSTHEATEXCHANGER

Maximize LNG station BOG recovery efficiency, eliminate water consumption, and guarantee hazardous-area safety with CSTHEATEXCHANGER:

  • Custom High-Pressure Transcritical CO2 Dry Coolers (50 kW to 1,500 kW+)

  • Rated for Operating Pressures up to 150 Bar

  • K65 High-Strength Copper-Iron or AISI 316L Stainless Steel Pressure Bundles

  • Certified ATEX / IECEx Zone 1 & Zone 2 Explosion-Proof Fan Drive Assemblies

  • 100% Waterless All-Weather Operation Down to −40∘C Sub-Zero Winter Climates

  • Full CE / PED & ASME Compliance, 100%100% Helium Leak Tested & Global Project Delivery

Contact our specialized cryogenic and high-pressure thermal engineering team today with your CO2 compressor mass flow rate (kg/hkg/h), gas inlet temperature and pressure (bar), target gas exit temperature, and hazardous area classification for comprehensive thermal simulation data and factory-direct proposals.

PHONE

International Business:+86 0519 8878 2189

Domestic business:+86 0519 8878 2190

QUICK LINKS

PRODUCTS

ABOUT US

When it comes to building heat exchanger for any application VRCOOLERTECH has the capability to meet your requirements.