+86 0519 8878 2189
News Center
Home / News / 120 kW Dry Cooler for High-Density ASIC Compute Clusters | CST

120 kW Dry Cooler for High-Density ASIC Compute Clusters | CST

Views: 0     Author: Site Editor     Publish Time: 2026-11-23      Origin: Site

At CSTHEATEXCHANGER, we design and manufacture high-efficiency 120 kW Closed-Circuit Dry Coolers and Air-Cooled Fluid Coolers specifically engineered for high-density liquid-cooled (Hydro/Water-Cooled) ASIC servers, GPU AI compute racks, single-phase immersion cooling tanks, and modular edge computing pods (delivering 120 kW heat rejection capacity at standard operating delta temperatures, fluid circulation flow rates from 15 to 22 m3/h, operating design pressures up to 1.6–2.5 MPa / 16–25 bar, and achieving annualized PUE<1.05–1.08). Built with seamless inner-grooved copper or AISI 304/316L stainless steel tubes, corrugated hydrophilic blue aluminum fins (or epoxy marine coatings), high-efficiency EC variable-speed inverter fan arrays, and integrated low-noise acoustic diffusers, CST 120 kW dry coolers dissipate 100% of high-density hashboard heat with zero water evaporation, maintain precise coolant supply temperatures (+35∘C to +45∘C+), prevent thermal throttling, and enable stable 20%–40% hardware overclocking.

CSTHEATEXCHANGER 120 kW Closed-Circuit Dry Coolers for High-Density ASIC Hydro &amp; Immersion Computing.jpg

1. Thermodynamic Sizing & Deployment: Sizing for 120 kW High-Density Compute Loads

In high-density liquid-cooled compute deployments (such as high-efficiency hydro-cooled ASIC servers or multi-pod immersion tanks), each computing unit generates high continuous heat flux. A 120 kW thermal envelope typically supports 18 to 24 units of high-performance hydro-cooled servers (at 5.3–6.0 kW5.3–6.0 kW each) or a multi-tank single-phase dielectric immersion setup:

        120 KW CLOSED-CIRCUIT DRY COOLER CLOSED LOOP INTEGRATION
        
   ======================= COMPUTE SERVER RACK / IMMERSION TANKS =======================
   ┌──────────────────────────────────────────────────────────────────────────────────┐
   │ [18 TO 24 UNITS HIGH-DENSITY HYDRO-COOLED SERVERS / IMMERSION PODS]              │
   │ • Water-glycol / Deionized water / Dielectric coolant loop (+60°C to +65°C return)│
   │ • High-performance water blocks directly cool hashboard chips                    │
   │ • Zero chassis air fans: Slashes noise (< 50 dBA) and parasitic power draw       │
   └────────────────────────────────────────┬─────────────────────────────────────────┘
                                            │ [HOT FLUID RETURN: +60°C @ 18 m³/h]
                                            ▼
   ======================= OUTDOOR 120 KW CLOSED-CIRCUIT DRY COOLER ==================
   ┌──────────────────────────────────────────────────────────────────────────────────┐
   │ [CST 120 KW V-BANK / HORIZONTAL MODULAR DRY COOLER]                              │
   │ • Seamless Copper / Stainless Tubes with Hydrophilic Blue Aluminum Fins          │
   │ • Dual / Quad High-Efficiency EC Variable Speed Inverter Fans (Modbus RTU)       │
   │ • Rejects 120 kW heat directly to ambient air (Zero water loss, PUE < 1.05)       │
   │ • Optional adiabatic pre-cooling pads for extreme desert heatwaves (> +42°C)     │
   └────────────────────────────────────────┬─────────────────────────────────────────┘
                                            │ [CHILLED FLUID SUPPLY: +38°C to +45°C]
                                            ▼
   ┌──────────────────────────────────────────────────────────────────────────────────┐
   │ Returns clean, closed-loop cooled liquid to servers, preventing thermal throttle │
   └──────────────────────────────────────────────────────────────────────────────────┘
================================================================================
CST 120 KW CLOSED DRY COOLER VS. TRADITIONAL WATER COOLING TOWERS
================================================================================
Evaluation Metric              CST 120 kW Closed-Circuit Dry CoolerTraditional Evaporative Cooling Tower
--------------------------------------------------------------------------------
Water Consumption Rate         0 Liters/Hour (100% Sealed Loop)Massive continuous water evaporation & makeup
Chip Micro-Channel Clogging    Zero Clogging (Closed clean fluid)Heavy mineral scaling blocks cold plates
Sub-Zero Winter Operation      Glycol Protection Down to -40°C  Severe risk of water basin freezing & burst
Power Usage Effectiveness (PUE)Ultra-Low: PUE 1.03 to 1.07      High: PUE 1.20 to 1.35 (Pump & fan heavy)
Chemical Water Treatment Cost  $0 Biocide & Anti-Scale Cost     High monthly chemical treatment bills
Fan Noise Level                Whisper Quiet (< 55–60 dBA @ 10m)Loud open splashing & heavy AC fan drone
Mobility & Installation Ease   Compact Plug-and-Play Skid (1 Day)Complex civil foundation, sump, & pumps
Server Overclocking Stability  Maintains tight chip temps for OC Thermal instability causes hash drops
================================================================================

1. 100% Sealed Loop: Protecting Micro-Channel Water Blocks from Scaling

High-density hydro-cooled server cold plates feature microscopic internal water channels (0.2–0.5 mm0.2–0.5 mm width). Open cooling towers introduce airborne dust, calcium, and mineral hardness that quickly scale and plug these micro-channels, causing catastrophic chip overheating. CST’s closed-circuit dry cooler circulates pure deionized water or treated glycol in a hermetically sealed loop with zero scale formation.

2. Ultra-Low PUE (<1.05<1.05) with Smart EC Fan Modulation

Equipped with brushless electronically commutated (EC) inverter fans, the 120 kW dry cooler dynamically modulates fan speed based on fluid temperature sensors. During nighttime hours and colder seasons, fan power drops by up to 60%60%, achieving an annualized Power Usage Effectiveness (PUE) below 1.05.

2. Metallurgy & Manufacturing Engineering: Heavy-Duty Industrial Coils & Casing

High-density compute thermal infrastructure operates under continuous 24/7/365 full electrical load:

        CST 120 KW DRY COOLER METALLURGICAL ANATOMY
        
   ┌─────────────────────────────────────────────────────────────────────────┐
   │ [1. BASE HEAT EXCHANGER TUBING]                                         │
   │ • Seamless Micro-Grooved Copper Tubes (Cu-DHP / ASTM B75).              │
   │ • Heavy-wall AISI 304 / 316L Stainless Steel for DI water loops.        │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [2. HIGH-PERFORMANCE EXTENDED FINS]                                     │
   │ • Corrugated Sine-Wave Hydrophilic Blue Aluminum Fins (Anti-dust/salt). │
   │ • Epoxy-Coated / Marine AlMg3 for high-saline coastal computing sites.  │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [3. RIGID STRUCTURAL ENCLOSURE & GUARDS]                                │
   │ • 2.5 mm Heavy Galvanized Steel with C4/C5-M Industrial Powder Coating. │
   │ • Stainless steel hardware, vibration dampers, & lifting lugs.          │
   └─────────────────────────────────────────────────────────────────────────┘
       CST 120 KW DRY COOLER PRODUCTION & TESTING WORKFLOW
       
   FROM HIGH-STRENGTH SEAMLESS TUBES & STAMPED CORRUGATED FINS
   ┌─────────────────────────────────────────────────────────────────────────┐
   │ [ STAGE 1: HYDRAULIC MANDREL EXPANSION (ZERO CONTACT THERMAL LOSS) ]    │
   │ High-tonnage expansion permanently locks tubes to fin collars           │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 2: ROBOTIC ORBITAL TIG / HIGH-SILVER AUTOMATED BRAZING ]        │
   │ Full-penetration header joints withstand high-pressure fluid pulses     │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 3: 100% HYDROSTATIC & HELIUM VACUUM LEAK TESTING ]              │
   │ Proof tested at 2.5 MPa (25 bar); Helium leak rate < 1x10⁻⁶ mbar·L/s    │
   ├─────────────────────────────────────────────────────────────────────────┤
   │ [ STAGE 4: FAN DYNAMIC BALANCING & DCIM INTEGRATION TEST ]              │
   │ Pre-wired IP65 control box with Modbus RTU / RS485 communication test   │
   └─────────────────────────────────────────────────────────────────────────┘
   DELIVERS MAXIMUM COMPUTING UPTIME & ZERO LEAK RELIABILITY

1. Highproof Pressure Containment (25 Bar25 Bar Proof Testing)

To handle pressure surges from high-head variable-frequency circulation pumps, every CST 120 kW dry cooler coil undergoes 100%100% hydrostatic proof testing at 2.5 MPa (25 bar)2.5 MPa (25 bar) and vacuum helium mass spectrometer testing, guaranteeing zero fluid loss and zero system downtime.

2. Optional Adiabatic Pre-Cooling for Extreme Summer Heatwaves (>+42∘C>+42∘C)

For facilities operating in hot desert or summer peak zones, CST provides integrated modular adiabatic evaporative misting pads. When ambient air exceeds +38∘C+38∘C, the system pre-cools incoming air by 8–12∘C8–12∘C, maintaining steady +42∘C+42∘C supply water to servers without spraying water onto the dry coil.

3. Product Configurations: 120 kW Dry Cooler Topologies

        CSTHEATEXCHANGER 120 KW DRY COOLER PORTFOLIO
        
   [1. CST-DC-120KW-FLAT (HORIZONTAL FLAT-BED / VERTICAL AIR DISCHARGE)]
   • Dual Ø 800 mm EC fan array; Ultra-compact footprint matching standard shipping pallets.
   • Ideal for individual container pods, rooftop mounts, and small 20-server modular arrays.
   ─────────────────────────────────────────────────────────────────────────────
   [2. CST-DC-120KW-VB (COMPACT V-BANK HIGH-EFFICIENCY MODULE)]
   • Dual V-angle coil geometry with 4x EC fans; Lower overall height profile for windy rooftops.
   • Sized for high-airflow density and easy access for seasonal coil washing.

4. Technical Specifications — 120 kW High-Density Compute Dry Cooler

(Note: The following engineering parameters represent standard manufacturing design envelopes for the 120 kW dry cooler model. Fluid connection ports, fin pitch, fan voltages, and casing metallurgy are 100% customized to specific server rack configurations.)

================================================================================
CST 120 KW HIGH-DENSITY COMPUTE DRY COOLER (CST-DC-120KW-HD)
================================================================================
Engineering Parameter           Standard Manufacturing & Design Range
--------------------------------------------------------------------------------
Nominal Heat Rejection Capacity 120 kW (410,000 BTU/h) @ Standard Design Ambient
Process Fluid Compatibility     Clean Water, 20%–35% Ethylene/Propylene Glycol, DI Water
Nominal Fluid Flow Rate Range   15.0 to 22.0 m³/h (66 to 97 GPM)
Fluid Temperature Envelope      Fluid In: +60°C (+140°F) / Fluid Out: +40°C to +45°C (+104°F)
Design Ambient Operating Range  -40°C to +50°C (-40°F to +122°F) All-Weather Certified
Design Operating Pressure Range Up to 1.6 MPa (16 bar / 232 psi) High-Pressure Certified
Hydrostatic Proof Test Pressure 2.5 MPa (25 bar / 362 psi) Leak Integrity Quality Gate
Core Tube Metallurgy Options    Seamless Copper (Cu-DHP Ø 5/8") or AISI 304/316L Stainless
Fin Metallurgy & Surface Finish Corrugated Hydrophilic Blue Aluminum / Epoxy-Coated
Fin Density / Pitch Envelope    10 to 14 FPI (Optimized for low air dP & dust shedding)
Fan Drive Technology            High-Efficiency EC (Electronically Commutated) Inverter Fans
Fan Quantity & Diameter         2x or 4x Ø 800 mm / Ø 910 mm High-Efficiency Sickle-Blade Fans
Total Fan Electrical Power Draw Approximately 1.8 kW to 3.2 kW (Stepless Modulation)
Acoustic Noise Pressure Level   Standard: 58–64 dBA @ 10m; Whisper-Quiet Package: < 52 dBA @ 10m
Fluid Connection Ports          DN65 / DN80 (2-1/2" / 3") PN16 / ANSI 150# Flanges or Victaulic
Casing & Structural Frame       2.5 mm Heavy Galvanized Steel + C4/C5-M Powder Coating (RAL 7035)
DCIM & Telemetry Communication  Native Modbus RTU (RS485), 0–10V Fan Speed Telemetry
Quality Standards & Compliance  CE / PED 2014/68/EU, ISO 9001:2015, RoHS Compliant
Testing & Quality Assurance     100% Helium Mass Spectrometer Testing + 25 Bar Hydrostatic Proof
================================================================================

5. Frequently Asked Questions (FAQ)

How many liquid-cooled servers can a 120 kW dry cooler support?

A 120 kW dry cooler typically supports 18 to 22 units of high-efficiency hydro-cooled servers operating at approximately 5.3–6.0 kW each under standard full-load hashing conditions, or up to 24 units under eco-mode operation.

Why is a dry cooler preferred over an evaporative cooling tower for hydro-cooled compute servers?

Hydro-cooled server cold plates have microscopic fluid channels that clog rapidly when exposed to calcium scaling and algae from open cooling towers. A dry cooler operates a 100%100% sealed, closed-circuit pure water or glycol loop, completely preventing scale buildup, eliminating water bills, and preventing winter freeze damage.

Can the dry cooler operate in hot summer ambient conditions above +40∘C?

Yes. With high fluid return temperatures (+60∘C to +65∘C), the dry cooler maintains an effective temperature difference (ΔT>15 K) even in +40∘C+40∘C ambient air. For extreme desert climates (>+45∘C), CST equips the cooler with automated adiabatic pre-cooling pads that lower intake air temperature without spraying water on the metal coil.

Source Custom 120 kW Compute Dry Coolers from CSTHEATEXCHANGER

Maximize compute uptime, eliminate water consumption, and unlock stable hardware overclocking with CSTHEATEXCHANGER:

  • Custom 120 kW Closed-Circuit Dry Coolers for High-Density Compute Clusters

  • Seamless Copper or AISI 316L Stainless Coils with Hydrophilic Blue Aluminum Fins

  • High-Efficiency EC Inverter Fan Arrays for Industry-Leading Ultra-Low PUE (<1.05)

  • 100% Sealed Loop Protection: Zero Scale, Zero Water Evaporation, All-Weather Operation

  • Heavy-Duty Weatherproof Casings with C4/C5-M Industrial Powder Coating

  • Full CE / PED Compliance, 100% Helium Mass Spectrometer Leak Tested & Fast Global Export

Contact our specialized high-density computing thermal engineering team today with your server quantities, power load (kW), target fluid temperatures, and site ambient conditions for custom CAD layout blueprints and factory-direct proposals.

PHONE

International Business:+86 0519 8878 2189

Domestic business:+86 0519 8878 2190

QUICK LINKS

PRODUCTS

ABOUT US

When it comes to building heat exchanger for any application VRCOOLERTECH has the capability to meet your requirements.
Copyright © 2021 Changzhou Vrcoolertech Refrigeration Co.,Ltd All rights reserved.  Sitemap  Manage Entrance