Immersion cooling is widely adopted for high‑density AI servers, GPU racks and ASIC mining hardware. Dry coolers serve as the outdoor heat‑rejection unit for single‑phase immersion tank setups, removing waste heat from the secondary glycol‑water loop connected to CDU or tank‑mounted heat exchangers.
In a typical immersion cooling workflow, IT hardware sits submerged inside dielectric fluid within immersion tanks. Heat transfers from hot hardware to dielectric liquid, then passes through a liquid‑to‑liquid heat exchanger into a closed glycol‑water secondary circuit. The hot glycol flows to the outdoor dry cooler; EC variable‑speed fans blow ambient air across fin‑tube coils to dissipate heat to atmosphere. Cooled glycol circulates back to the immersion tank to complete the cooling loop.
Key advantages of dry coolers for immersion cooling projects:
Closed‑loop dry operation, nearly zero water consumption; no legionella risk compared with cooling towers
Full free‑cooling capability, greatly cuts energy consumption and helps lower overall PUE
Modular capacity design, flexible for small container‑style immersion sites up to large‑scale data‑center farms
EC variable‑speed fan configuration, adjusts airflow according to real‑time heat load for energy saving
Optional adiabatic spray add‑on to boost cooling capacity under high‑ambient summer temperatures
Anti‑corrosion coil coating options available for coastal or dusty outdoor installation environments
Compatible with single‑phase immersion tanks, rack‑style immersion enclosures and containerized mining deployments
Dry coolers are the preferred heat rejection solution for immersion‑based data centers, AI computing facilities and crypto‑mining farms, especially for water‑limited locations where cooling towers are not practical.
CST Heat Exchanger provides custom dry coolers tailored for immersion cooling. Available capacities range from small‑size 40kW units up to multi‑megawatt large modules, supporting horizontal, V‑type layout, BMS communication interface and various anti‑corrosion treatments.
CSTHEATEXCHANGER Industrial Air-Cooled Dehumidifiers for Marine Spray Coating and Blast Paint Plants
CSTHEATEXCHANGER Plate Heat Exchangers for Immersion Cooling Systems
CSTHEATEXCHANGER All-in-One Container Data Centers: Complete Engineering & Sizing Guide
CSTHEATEXCHANGER Dry Coolers for Submerged Digital Mining and Dielectric Oil Systems
CSTHEATEXCHANGER Stainless Steel Shell And Tube Heat Exchangers for Biogas Dryer Processes
CSTHEATEXCHANGER V-Type Cooling Coils for Small Vertical Air Handling Units (AHUs)
CSTHEATEXCHANGER Evaporator Coils for Plastic Drying Dehumidifiers
CSTHEATEXCHANGER 5MW Cooling Capacity Dry Coolers for Crypto Mining Farms with Water-Cooled Miners
CSTHEATEXCHANGER Monoblock Refrigeration Units for Refrigerated and Frozen Products
International Business:+86 0519 8878 2189
Domestic business:+86 0519 8878 2190