Views: 0 Author: Site Editor Publish Time: 2026-09-20 Origin: Site
We have developed a 50 m² shell-and-tube heat exchanger for use in a vacuum frying system. The unit is designed to transfer heat between palm oil at 110°C and mineral oil at 130°C, supporting indirect heating for the vacuum fryer process.
In a vacuum fryer, stable and controllable heat transfer is essential for maintaining consistent process conditions. This shell-and-tube heat exchanger separates the palm-oil circuit from the mineral-oil circuit while allowing thermal energy to pass through the heat-transfer surface.
Under the stated operating conditions, the hotter mineral oil transfers heat to the palm oil. The separation of the two fluids helps the system maintain an indirect heating process and allows the heat exchanger to be integrated into the customer’s vacuum-frying equipment according to the project layout.
The heat exchanger provides a nominal heat-transfer area of 50 m². Its shell-and-tube construction consists of a shell, tube bundle, tube sheets, internal supports, and process connections. The final internal arrangement, materials, tube dimensions, flow path, and connection configuration are selected according to the customer’s process data and approved technical drawings.
The confirmed project information is as follows:
Item | Confirmed information |
|---|---|
Equipment type | Shell-and-tube heat exchanger |
Application | Vacuum fryer |
Heat-transfer area | 50 m² |
Hot-side fluid | Mineral oil |
Hot-side temperature | 130°C |
Cold-side fluid | Palm oil |
Palm-oil temperature | 110°C |
Heat-transfer method | Indirect heat exchange |
The actual heat duty, flow rates, outlet temperatures, pressure drop, design pressure, design temperature, and material selection must be confirmed through the complete thermal and mechanical design.
Shell-and-tube heat exchangers are widely used for industrial heating and cooling because the two process fluids flow through separate passages. The structure can be adapted to different operating pressures, temperatures, fluid properties, and installation requirements.
For this vacuum-fryer application, we review the palm-oil and mineral-oil operating conditions when selecting the tube-side and shell-side flow arrangement. We also consider the required heat-transfer capacity, allowable pressure drop, cleaning requirements, connection orientation, support structure, and available installation space.
The final design should also take into account the viscosity of the process fluids at operating temperature, start-up and shut-down conditions, thermal expansion, sealing requirements, and the customer’s safety and maintenance procedures.
We can customize the 50 m² shell-and-tube heat exchanger according to the customer’s drawings, process data, and vacuum-fryer layout. Our engineering team can support the following design items:
Heat-transfer area and thermal duty
Shell-side and tube-side flow arrangement
Palm-oil and mineral-oil connection configuration
Tube material and shell material
Tube diameter, tube length, and tube count
Tube-sheet and baffle design
Design pressure and design temperature
Inlet and outlet connection sizes
Drain, vent, inspection, and maintenance provisions
Overall dimensions and installation supports
Surface treatment and insulation requirements
Before production, we confirm the technical drawings, operating conditions, material requirements, inspection requirements, and delivery specifications with the customer.
We manufacture the heat exchanger according to the approved drawings and technical documents. During production, we inspect the tube bundle, tube-to-tube-sheet joints, shell assembly, connections, supports, and overall dimensions.
The completed unit is subject to the inspection and testing requirements agreed for the project. These may include visual inspection, dimensional inspection, pressure or leakage testing, weld inspection, and connection verification, depending on the customer’s technical specification.
We provide customized heat exchanger solutions for industrial heating, cooling, heat recovery, refrigeration, HVAC, and process equipment. For vacuum-fryer applications, we focus on matching the heat exchanger to the actual fluids, temperatures, flow conditions, equipment layout, and maintenance requirements rather than selecting a model based on heat-transfer area alone.
If you need a shell-and-tube heat exchanger for palm-oil and mineral-oil heating, please send us the required flow rates, inlet and outlet temperatures, operating and design pressures, fluid properties, connection details, and installation drawings. We will review the data and provide a suitable customized solution.
The confirmed nominal heat-transfer area is 50 m².
The stated application uses palm oil on one side and mineral oil on the other side.
The palm-oil temperature is 110°C, and the mineral-oil temperature is 130°C.
The hotter mineral oil transfers heat through the heat-transfer surface to the palm oil. The two fluids remain in separate flow circuits.
No. The heat-transfer area is one important design input, but final selection also requires flow rates, inlet and outlet temperatures, fluid properties, pressure limits, connection data, and installation conditions.
Yes. We can customize the structure, materials, tube bundle, connections, dimensions, supports, and inspection requirements according to the customer’s process and drawings.
Please provide the heat duty, flow rates, inlet and outlet temperatures, operating and design pressures, fluid properties, connection sizes, installation space, material requirements, and applicable inspection standards.
International Business:+86 0519 8878 2189
Domestic business:+86 0519 8878 2190