+86 0519 8878 2189
News Center
Home / News / What is the advantage and disadvantage of data center immersion cooling?

What is the advantage and disadvantage of data center immersion cooling?

Views: 22     Author: Site Editor     Publish Time: 2023-03-03      Origin: Site

Data center immersion cooling is a method of cooling servers and other computer equipment by immersing them in a non-conductive liquid. The liquid removes heat more efficiently than air, which is the traditional cooling method used in most data centers.


There are different types of immersion cooling systems, but they all work by submerging the computer hardware in a specially designed tank filled with a dielectric liquid. The liquid flows through the equipment and absorbs the heat generated by the components. It then carries the heat away from the hardware and transfers it to a heat exchanger where it is dissipated into the environment.


One of the advantages of immersion cooling is that it can significantly increase energy efficiency by reducing the amount of energy needed for cooling. This is because the liquid can remove heat more effectively than air, and can be maintained at a constant temperature, resulting in less energy required to keep the hardware cool.


Another benefit is that immersion cooling can also reduce the physical footprint of a data center. Because the hardware is submerged in the cooling liquid, there is no need for large air conditioning units, air ducts, or other cooling infrastructure. This can lead to smaller data center footprints, lower construction costs, and greater flexibility in where data centers can be located.


However, immersion cooling also has some drawbacks, such as the initial capital costs for the immersion cooling system and the need to replace the cooling liquid periodically. Additionally, some hardware may not be compatible with immersion cooling, and it can be more difficult to access the hardware for maintenance or upgrades.


Despite these challenges, immersion cooling is becoming increasingly popular in the data center industry, particularly for high-performance computing applications that generate a lot of heat.


A dry cooler is a type of cooling system that uses air to dissipate heat from a liquid coolant. Dry coolers are often used in conjunction with other cooling systems, such as immersion cooling or liquid cooling, to remove the heat from the coolant that has been heated by the equipment.


In a data center immersion cooling system with a dry cooler, the coolant is circulated through the submerged computer hardware to absorb heat, as in a traditional immersion cooling system. However, instead of using a liquid-to-liquid heat exchanger to remove the heat from the coolant, a dry cooler is used to dissipate the heat directly into the air.


The coolant from the immersion cooling system is pumped to a heat exchanger, where it transfers the heat to the air that is flowing through the heat exchanger. The heated air is then expelled from the data center through a vent or exhaust system, while the cooled coolant is recirculated back into the immersion cooling system.


The dry cooler system is often used in conjunction with an immersion cooling system because it allows for more efficient cooling by utilizing the natural properties of air, such as the higher heat capacity and the ability to remove heat through convection. Additionally, dry coolers do not require any additional cooling water, making them more environmentally friendly and cost-effective.


Dry coolers are also beneficial in areas with a dry climate or low humidity, where the air is naturally cooler and can more effectively remove heat from the coolant. However, in areas with high humidity, the effectiveness of the dry cooler may be reduced, as the moisture in the air can interfere with the cooling process.


To optimize the performance of a data center immersion cooling system with a dry cooler, it is important to carefully consider the design and placement of the dry cooler units. The size and number of dry coolers needed will depend on the size and heat output of the data center, as well as the local climate and environmental conditions.


In addition, it is important to regularly maintain and clean the dry cooler units to ensure optimal performance and prevent any buildup of dirt or debris that can reduce cooling efficiency.


data center immersion cooling system with a dry cooler can provide an efficient and effective cooling solution for high-performance computing applications, while also reducing energy consumption and environmental impact. Careful design and maintenance of the dry cooler units are important to optimize performance and ensure reliable operation over the long term.


Another advantage of a data center immersion cooling system with a dry cooler is that it can be more reliable than traditional air-cooled systems. Traditional air-cooled systems are prone to failures due to issues such as 

dust buildup, air conditioning malfunctions, and power outages. With an immersion cooling system, there are no moving parts or air filters to maintain, which can lead to greater reliability and reduced downtime.


Moreover, the use of a dry cooler in an immersion cooling system can also lead to greater flexibility in the design and placement of data centers. Since dry coolers do not require a source of cooling water, they can be placed in more remote locations or areas without access to a reliable water supply.


However, one potential drawback of a data center immersion cooling system with a dry cooler is that it can be more expensive to install than traditional air-cooled systems. The cost of the dry cooler units, as well as the additional piping and electrical infrastructure required, can add to the overall cost of the system. Additionally, there may be some additional costs associated with the maintenance and operation of the dry cooler units.


Another consideration for a data center immersion cooling system with a dry cooler is the potential impact on noise levels. Dry cooler units can generate noise during operation, which may be a concern for data center operators who need to maintain a quiet environment.


To mitigate noise concerns, it is important to carefully select dry cooler units that have low noise levels and to consider the placement of the units in relation to the data center. In some cases, it may be necessary to install noise-reducing barriers or other sound-absorbing materials to minimize the impact of the dry cooler noise.


In addition, it is important to consider the environmental impact of a data center immersion cooling system with a dry cooler. While dry coolers are more environmentally friendly than traditional air-cooled systems, they still require a significant amount of energy to operate. This energy usage can contribute to greenhouse gas emissions and other environmental concerns, particularly in areas where the electricity is generated from fossil fuels.


To minimize the environmental impact of a data center immersion cooling system with a dry cooler, it is important to select energy-efficient units and to optimize the overall design and operation of the system. This may include implementing energy-saving measures such as free cooling, where the dry cooler is used to cool the coolant when the outside air is cool enough, rather than relying on mechanical refrigeration.


In summary, a data center immersion cooling system with a dry cooler can provide a reliable and efficient cooling solution for high-performance computing applications. However, careful consideration of factors such as noise levels and environmental impact is necessary to ensure optimal performance and minimize any potential drawbacks.


data center cooling 2


PHONE

International Business:+86 0519 8878 2189

Domestic business:+86 0519 8878 2190

QUICK LINKS

PRODUCTS

ABOUT US

When it comes to building heat exchanger for any application VRCOOLERTECH has the capability to meet your requirements.
Copyright © 2021 Changzhou Vrcoolertech Refrigeration Co.,Ltd All rights reserved.  Sitemap  Manage Entrance