Home / News / Free Cooling Dry Cooler for Data Centre

Free Cooling Dry Cooler for Data Centre

Views: 2     Author: Site Editor     Publish Time: 2023-04-13      Origin: Site

Free cooling dry cooler for data centre

Free cooling dry coolers can be a cost-effective and energy-efficient option for cooling data centers. Here are some additional details about free cooling dry coolers:


How they work: Free cooling dry coolers use the outdoor air to cool the data center, without the need for mechanical refrigeration. The dry cooler circulates the outdoor air through a heat exchanger to remove the heat from the data center, and then exhausts the warmed air back outside. The efficiency of free cooling depends on the outdoor air temperature and humidity levels, but can provide significant energy savings in cooler climates.


Types of free cooling: There are two main types of free cooling: direct and indirect. Direct free cooling uses the outdoor air directly to cool the data center, while indirect free cooling uses a heat exchanger to separate the outdoor air from the data center air, preventing any contaminants or humidity from entering the data center.


Efficiency: Free cooling dry coolers can be highly efficient, especially in areas with cooler climates. The energy savings can be significant, with some estimates showing up to 80% reduction in energy consumption compared to traditional mechanical cooling systems.


Environmental benefits: Free cooling dry coolers are an environmentally-friendly option for cooling data centers, as they do not require the use of refrigerants or other harmful chemicals. Additionally, they can reduce the carbon footprint of the data center by reducing energy consumption and greenhouse gas emissions.


Free cooling dry cooler for data centre


Cost savings: The energy savings from free cooling dry coolers can result in significant cost savings over the life of the equipment. Additionally, many utility companies offer incentives and rebates for the installation of energy-efficient equipment, which can further reduce the upfront cost of the equipment.


Maintenance: Free cooling dry coolers require regular maintenance to ensure optimal performance and longevity. This includes cleaning the heat exchanger to remove dirt and debris, inspecting the fans and motors, and checking the controls and sensors to ensure they are functioning properly.


Design considerations: The design of the data center and the location of the dry cooler can impact the efficiency of the free cooling system. Factors such as the orientation of the data center, the size and location of the dry cooler, and the ventilation system all need to be considered to ensure optimal performance and energy efficiency.


Temperature range: Free cooling dry coolers can provide cooling for data centers in a wide range of outdoor temperatures, depending on the design of the system. In colder climates, free cooling can be used for most of the year, while in warmer climates, free cooling may only be available during the cooler months.


Control systems: Free cooling dry coolers require sophisticated control systems to ensure optimal operation and energy efficiency. These systems can monitor the outdoor temperature and humidity levels, adjust the airflow through the heat exchanger, and switch between free cooling and mechanical cooling as needed to maintain the desired indoor conditions.


Backup systems: In the event of a failure of the free cooling system, backup mechanical cooling systems may be required to maintain the indoor conditions in the data center. These backup systems can include traditional air conditioning units, chilled water systems, or other cooling equipment.


Air filtration: Free cooling dry coolers can be equipped with air filtration systems to remove contaminants from the incoming air, such as dust, pollen, and other particulates that can reduce the efficiency of the cooling system and damage the computer equipment. HEPA filters can be used to provide high levels of filtration and protect the sensitive equipment from damage.


Humidity control: Free cooling dry coolers require precise humidity control to prevent damage to the computer equipment and ensure reliable operation. Humidification or dehumidification systems may be required to maintain the desired humidity levels in the data center.


Noise reduction: Free cooling dry coolers can generate significant noise levels, which can be a concern in data centers. To reduce the noise, acoustic enclosures can be installed around the dry coolers, or the dry coolers can be located outside of the data center and connected to the indoor units with ductwork.


Maintenance: Free cooling dry coolers require regular maintenance to ensure optimal performance and longevity. This includes cleaning the heat exchanger to remove dirt and debris, inspecting the fans and motors, and checking the controls and sensors to ensure they are functioning properly.


Cost savings: Free cooling dry coolers can provide significant energy savings over traditional mechanical cooling systems, resulting in lower operating costs and a faster return on investment. Additionally, the installation of free cooling dry coolers may qualify for rebates and incentives from utility companies and government agencies, further reducing the upfront cost of the equipment.