At CSTHEATEXCHANGER, we design and manufacture high-efficiency Direct-to-Chip (DTC) Coolant Distribution Units (CDUs) integrated with customized Brazed Plate Heat Exchangers (BPHE) engineered specifically for hyperscale AI data centers, high-density GPU supercomputers (NVIDIA H100/H200/GB200 NVL72, AMD MI300X), and enterprise HPC liquid cooling infrastructures (scalable thermal capacities engineered from 50 kW in-rack modules to over 1.5 MW in-row and floor-standing CDUs). Utilizing high-grade AISI 316L stainless steel plates or Titanium plates vacuum-brazed with pure Copper (99.9%) or high-purity Nickel alloys, our CDU brazed plate heat exchangers provide complete hydraulic isolation between primary facility water and secondary technology cooling loops. Featuring optimized chevron/herringbone plate corrugation patterns that induce micro-turbulent fluid flow at low pressure drops (ΔP<35 kPa), our heat exchangers deliver an ultra-tight thermal approach temperature of 1.5K to 3.5K, enabling warm-water cooling (+32∘C to +45∘C facility supply water) and year-round 100% free cooling with zero chiller compressor power, maximizing AI computing density at sub-1.02 PUE.
Direct-to-Chip (DTC) liquid cooling routes coolant directly over CPU/GPU cold plates with micro-channel fin gaps (<0.1 mm). The Brazed Plate Heat Exchanger inside the CDU acts as the thermal transfer core and hydraulic firewall between building utilities and server loops:
HYDRAULIC DECOUPLING IN DIRECT-TO-CHIP (DTC) CDUs
=================== PRIMARY FACILITY WATER SYSTEM (FWS) ===================
[ External Dry Coolers / Cooling Towers / Chilled Water Loops: +30°C to +42°C ]
│ ▲
2-Way Modulating Valve FWR Return to Utility
│ │
▼ │
┌────────────────────────────────────────────────────────────────────────────┐
│ CSTHEATEXCHANGER® CUSTOM BRAZED PLATE HEAT EXCHANGER (BPHE) CORE │
│ • AISI 316L Stainless Steel / Titanium Corrugated Chevron Plates │
│ • Vacuum-Brazed Pure Copper (99.9%) or Nickel Alloy Matrix │
│ • Approach Temp: 1.5K - 3.5K | Pressure Drop: ΔP < 25 - 35 kPa │
│ • Complete Physical Hydraulic Barrier (Zero Cross-Contamination) │
└─────────────────────┬────────────────────────────────┬─────────────────────┘
│ ▲
Cold Coolant Supply: +35°C to +45°C Warm Return: +50°C to +60°C
│ │
▼ │
================ SECONDARY TECHNOLOGY COOLING SYSTEM (TCS) ================
[ Sealed Deionized / Inhibited PG25 Loop: GPU / CPU Micro-Channel Cold Plates ] Primary Loop (Facility Water System - FWS): Connects to ambient dry coolers, adiabatic cooling towers, or central facility chillers. Operates with standard treated industrial water or glycol.
Secondary Loop (Technology Cooling System - TCS): Dedicated, closed, ultra-clean loop containing deionized water or specialized low-viscosity inhibited propylene glycol (PG25) feeding server cold plates, manifolds, and quick disconnects.
A tight thermal approach between primary supply and secondary supply allows data centers to operate with warm facility water (+32∘C to +45∘C, conforming to ASHRAE Liquid Cooling Classes W3, W4, and W5). This eliminates the capital expense and electrical parasitic load of central chillers by enabling year-round free cooling via ambient dry coolers.
CSTHEATEXCHANGER engineers every CDU plate pack using precision-stamped plate geometry and high-vacuum brazing furnaces:
================================================================================
CSTHEATEXCHANGER CDU BRAZED PLATE HEAT EXCHANGERS VS. GENERIC EXCHANGERS
================================================================================
Engineering Feature Generic Brazed Plate Exchangers CSTHEATEXCHANGER High-Density CDU BPHEs
--------------------------------------------------------------------------------
Plate Metallurgy & Grade Standard SS304 (Pitting Risk) Deep-Draw AISI 316L / Titanium Gr.1
Brazing Alloy Options Standard Copper Brazing Only Pure Copper (99.9%) & High-Purity Nickel
Brazing Quality Standard Atmospheric Gas Belt Furnace High-Vacuum Electric Furnace (< 10⁻⁴ mbar)
Chevron Corrugation Geometry Single Angle Low-Theta Pattern Engineered Mixed High/Low Theta Patterns
Thermal Approach Temperature 5.0K to 8.0K Ultra-Tight 1.5K to 3.5K Approach
Secondary Loop Fluid Pressure ΔP > 55 - 75 kPa (High Head) Ultra-Low ΔP < 25 - 35 kPa (Low Pumping Power)
Internal Fluid Hold-Up Volume Large (High Coolant Weight) Optimized Thin-Gap Channels (< 1/4 Volume)
Helium Leak Detection Standard Hydrostatic Water Dip Only 100% Mass Spec Helium Test (< 1x10⁻⁶ mbar·l/s)
Design Proof Pressure Rating 16 to 20 bar 30 to 45 bar (Burst Pressure > 120 bar)
================================================================================ CST CORRUGATED CHEVRON PATTERN & HIGH-TURBULENCE MIXING
PRIMARY FACILITY WATER (FWS) SECONDARY TECHNOLOGY COOLANT (TCS)
┌───┬───┬───┬───┬───┬───┬───┐ ┌───┬───┬───┬───┬───┬───┬───┐
│ ╲ │ ╱ │ ╲ │ ╱ │ ╲ │ ╱ │ ╲ │ ◄──────► │ ╱ │ ╲ │ ╱ │ ╲ │ ╱ │ ╲ │ ╱ │
│ ╱ │ ╲ │ ╱ │ ╲ │ ╱ │ ╲ │ ╱ │ │ ╲ │ ╱ │ ╲ │ ╱ │ ╲ │ ╱ │ ╲ │
└───┴───┴───┴───┴───┴───┴───┘ └───┴───┴───┴───┴───┴───┴───┘
Continuous Counter-Current Flow Matrix with Micro-Vortex Boundary Layer Scrubbing Our engineering team utilizes asymmetric and mixed chevron angle plate pressings. High-theta angles maximize thermal transfer coefficients (>7,500 W/m2⋅K) for viscous glycol blends, while low-theta channels minimize hydraulic resistance, reducing secondary pump power consumption by up to 30%.
While copper brazing is standard for glycol/water loops, CSTHEATEXCHANGER supplies vacuum-brazed Nickel-alloy plate exchangers for ultra-pure deionized water (<0.1 μS/cm) applications. Nickel brazing eliminates copper ion leaching, ensuring zero electrochemical galvanic corrosion across aluminum or nickel-plated cold plates inside server blades.
CSTHEATEXCHANGER supplies custom BPHE cores and complete modular CDU packages across all data center deployment scales:
CSTHEATEXCHANGER CDU FORM FACTORS & APPLICATIONS
[1. IN-RACK DIRECT-TO-CHIP CDUs (40 kW - 120 kW)]
• 4U to 8U EIA-310 standard 19" or 21" OCP slide-out rack chassis.
• Dedicated thermal management for individual high-density AI server racks.
─────────────────────────────────────────────────────────────────────────────
[2. IN-ROW DIRECT-TO-CHIP CDUs (200 kW - 600 kW)]
• Same footprint as standard 300 mm / 600 mm server cabinets.
• Feeds secondary coolant manifolds across 4 to 8 adjacent high-density racks.
─────────────────────────────────────────────────────────────────────────────
[3. CENTRAL FLOOR-STANDING CDUs (800 kW - 1.5 MW+)]
• Centralized high-capacity pump and BPHE skid serving entire data hall pods.
• Multi-BPHE parallel configurations with full N+1 or 2N mechanical redundancy. (Note: The following engineering parameters represent standard manufacturing design envelopes. Exchanger dimensions, port diameters, flow rates, and materials are customized to project-specific thermal dissipation requirements and rack constraints.)
================================================================================
CSTHEATEXCHANGER DIRECT-TO-CHIP CDU & BPHE HEAT EXCHANGER SERIES
================================================================================
Engineering Parameter Standard Manufacturing & Design Range
--------------------------------------------------------------------------------
Thermal Cooling Capacity Range 50 kW to 1,500+ kW (In-Rack, In-Row, and Floor CDUs)
Heat Exchanger Core Type Vacuum-Brazed Plate Heat Exchanger (BPHE) / Dual Core
Plate Metallurgy Options AISI 316L Stainless Steel (1.4404), Titanium Gr. 1, Hastelloy
Brazing Material Options Pure Copper (99.9%) or High-Purity Nickel Alloy (BNi-2)
Thermal Approach Temperature Ultra-Tight 1.5K to 3.5K @ Rated Flow & Heat Load
Primary Water Supply (FWS) Temp +20°C to +45°C (Compatible with Free Cooling Dry Coolers)
Secondary Technology Supply +25°C to +50°C (Optimized for Direct-to-Chip GPU Cold Plates)
Secondary Coolant Compatibility Deionized Water (DI), PG25/EG25 (Inhibited Glycol), Novec
Pressure Drop (Secondary TCS) Ultra-Low: ΔP < 25 to 35 kPa (3.6 to 5.0 psi)
Operating Pressure Rating Primary: 16 - 25 bar | Secondary: 10 - 16 bar
Proof / Burst Pressure Limits Proof: 35 - 45 bar | Burst Pressure: > 120 bar
Leakage Verification Standard 100% Mass Spectrometer Helium Leak Testing (< 1x10⁻⁶ mbar·l/s)
Port & Hydraulic Connections Victaulic Grooved, ISO 16028 Quick Disconnects, ANSI Flanged
Pump Redundancy Architecture N+1 or 2N Canned-Motor / Mag-Drive ECM Pumps (< 50 ms Failover)
Filtration & Fluid Conditioning 50 µm / 20 µm Duplex Stainless Steel Filter + Micro-Deaerator
Control & Telemetry Protocols Redfish API, SNMP v3, Modbus TCP/RTU, BACnet IP, Dual GbE LAN
Safety & Compliance Standards UL 62368-1, CE / PED 2014/68/EU, ASME Sec. VIII, RoHS, REACH
================================================================================ BPHEs provide the highest thermal density per unit volume (occupying less than 20% of the space of a shell-and-tube exchanger), have zero elastomer gaskets that can degrade or leak over time, require minimal internal fluid volume, and achieve ultra-tight thermal approaches (<2K<2K) impossible with traditional shell-and-tube designs.
Nickel-brazed BPHEs are essential when using ultra-pure deionized water (DI water) in the secondary loop. Pure DI water can leach trace copper ions from standard copper-brazed exchangers, causing electrical conductivity increases and promoting galvanic pitting corrosion on aluminum micro-channel cold plates inside servers.
A 2K approach temperature allows the secondary coolant loop to operate just 2∘C above the facility water. When ambient outdoor air is +30∘C, the dry cooler can deliver +35∘C water to the CDU, which in turn delivers +37∘C coolant directly to GPU cold plates. This eliminates mechanical chiller compressors entirely, reducing data center cooling power by up to 80% and driving PUE down to <1.02.
Empower your AI cluster deployments with robust, ultra-compact liquid cooling infrastructure from CSTHEATEXCHANGER:
Custom Brazed Plate Heat Exchanger Cores for In-Rack (50 kW–120 kW), In-Row (200 kW–600 kW), and Central (1.5 MW+) CDUs
AISI 316L Stainless Steel & Titanium Plates with Pure Copper or Nickel Vacuum Brazing
Ultra-Tight Thermal Approach (1.5K to 3.5K) & Low Secondary Pressure Drop (ΔP<25 kPa)
Integrated Complete CDUs with N+1 Canned-Motor Redundant Pumps & Duplex Filtration
100% Helium Mass Spectrometer Leak Tested to Industrial Supercomputing Standards
Full OEM/ODM Thermal Simulation (CFD), 2D/3D CAD Models, and Factory-Direct Supply
Contact our specialized data center thermal engineering team today with your target rack heat load (kWkW), primary water supply temperatures, allowable pressure drop, and secondary loop fluid specifications for custom thermal modeling, engineering drawings, and factory-direct quotations.